If a failure occurs during downloading or decompression, the new version is
erased from the flash and the backup version becomes active. In this case, only
one version is left stored in the flash memory. If the active software becomes
corrupted, you can replace it with its backup.
Installing a New Software Release via TFTP
³ To install a new software release via TFTP:
1. From the SW & File Transfer menu, select TFTP (
Figure
4-46
) (Main menu >
File Utilities > SW & File Transfer > SW Download > TFTP).
ASMi-52
TFTP
TFTP status (No operation)
TFTP error (No error)
TFTP IP server (172.17.160.103)
TFTP file name (201e24.img)
TFTP retry timeout (sec) [0-300] (15)
TFTP total timeout (sec) [0-4000] (1200)
Save
Transfer command
>
ESC - prev. menu ; ! – main menu ; & – exit
Figure
4-46. TFTP Menu
2. From the TFTP menu, perform the following steps:
Select TFTP IP Server and enter the IP address of the TFTP server
Select TFTP File Name and enter the name of the software file (for
example, 201e24.img).
Select TFTP Retry Timeout and specify intervals between connection
retries (in seconds).
Select TFTP Total Timeout and specify the TFTP connection timeout (in
seconds).
Select Save to save the TFTP configuration.
Select Transfer Command to start downloading file to ASMi-52.
ASMi-52 automatically erases the backup partition. Once downloading is
completed, ASMi-52 saves the new release as an active partition, the
former active partition becomes the backup.
Once downloading is complete, ASMi-52 decompresses the release file,
displaying the following message:
Final process download. Reset
After the decompression, ASMi-52 saves the new release as an active
partition, the former active partition becomes backup. Then the unit