Specifications
ASMi-52L Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics
Testing ASMi-52L 6-13
The Diagnostics menu is displayed (see Figure 6-12).
2. From the Diagnostics menu, select:
Local Test to run the LLB on the local ASMi-52L
Remote Test to run the LLB on the remote ASMi-52L.
The Local/Remote Test menu appears (see Figure 6-13).
3. Select LLB.
The LLB value in parenthesis changes to ON. Also, an additional
parameter, Loop Timeout, is displayed for the local ASMi-52L.
4. Select Loop Timeout, if you want to set loopback timeout (in minutes).
The Loop Timeout value changes.
Avoid setting timeout to 0 as local control is lost during LLB. 0=Forever
5. Once you selected the loopback timeout, select Save to activate the LLB.
The LLB is initiated. The TST indicator lights up and the ASMi-52L units
lose synchronization.
ASMi-52L
Diagnostics
1. Local Test >
2. Remote Test >
3. Repeater Test >
>
ESC-previous menu ; !–main menu ; &–exit terminal
Figure 6-12. Diagnostics Menu
ASMi-52L
Local Test or Remote Test
LLB from DTE: OFF
RLB from DTE: OFF
1. LLB (ON)
2. Loop Timeout (min)(0-4095) ...(5)
3. LEDs test
4. Clear all
5. Save
>
ESC-previous menu ; !–main menu ; &–exit; @-scroll
Figure 6-13. Local/Remote Test Menu
Note