Specifications
Chapter 4 Configuration ASMi-52L Installation and Operation Manual
4-30 Additional Tasks
Resetting ASMi-52L
ASMi-52L supports four types of reset:
• Reset to the default setting
• SHDSL interface reset
• SHDSL repeater line reset.
• Overall reset
Resetting to Default Settings
You can reset the local or remote ASMi-52L to default settings. Resetting to the
factory default does not affect the master clock setting. In addition, you can reset
the local ASMi-52L without affecting its management parameters (IP address, mask
and default gateway).
To reset ASMi-52L to the factory default:
1. Display the Factory Default menu. (Path: Main menu > Configuration >
System Configuration > Factory default)
Factory Default menu is displayed (Figure 4-34).
ASMi-52L
Factory default
1. Local factory default ...
2. Remote factory default ...
3. Local factory default W/O MNG ...
4. Remote factory default W/O MNG ...
>
ESC - prev. menu ; ! – main menu ; & – exit
Figure 4-34. Factory Default Menu
2. From the Factory Default menu, perform one the following steps:
Select Local Factory Default to reset the local ASMi-52L.
Select Remote Factory Default to reset remote device.
Select Local Factory Default W/O MNG to reset all parameters, except for
IP address, mask, default gateway and manager list of the local ASMi-52L.
Select Remote Factory Default W/O MNG to reset all parameters, except
for IP address, mask, default gateway and manager list of the remote
ASMi-52L.
Local/Remote Factory Default W/O MNG parameters are available only for the units
equipped with the management LAN port.
ASMi-52L displays the following message:
Request to factory default !!! Confirm Y/N
3. Type Y to confirm the reset.
ASMi-52L resets all configuration parameters, except for the master clock
(and IP values), to their default settings and restarts the system.
Note