Specifications
ASMi-52L Installation and Operation Manual Chapter 3 Operation
Configuration Alternatives 3-7
2. Open the Web browser.
3. Disable any pop-up blocking software, such as Google Popup Blocker.
4. Enter the IP address of the ASMi-52L in the address field of the browser in the
following format: http://’IP address’ and then press <Enter> to command the
browser to connect (‘IP address’ stands for the actual ASMi-52L IP address
which has to be assigned via an ASCII terminal).
5. After the opening window is displayed, click LOGIN.
6. Enter your user name and password.
The Main menu is displayed.
Navigating the ConfiguRAD Menus
ConfiguRAD is a Web-based remote access terminal management software. It
provides a user-friendly interface for configuring, collecting statistics and
performing diagnostic tests on the ASMi-52L units.
To choose an option:
1. Click a link in the ConfiguRAD screen to display the next menu.
2. Once the target screen is displayed, select a value from the drop-down box or
enter it in a text box.
At the left-hand bottom corner, ConfiguRAD provides some auxiliary management
tools:
• Status – shows the number of users currently managing ASMi-52L
• Trace – opens an additional pane for system messages, progress indicators
(ping, software and configuration file downloads) and alarms. It is
recommended to keep the trace pane open all the time.
• Refresh All – refreshes performance registers.
Configuring via RADview
The RADview ASMi-52L Element Manager main window provides a dynamically
updated representation of ASMi-52L, allowing you to monitor and manage the
ASMi-52L. The main window displays the device hardware configuration, showing
the system and existing ports.
The following rows are displayed in the main window:
• System
• Network port
• User port
There are two levels of objects, System Level and Port Level:
1. System Level - This level contains all the parameters/functions common to the
whole device. To manipulate the system level object, you must first select its
row.
2. Port Level - This level contains all the parameters/functions of selected port. To
manipulate a port level object, you must first select its row.