Specifications

ASMi-52L Installation and Operation Manual Chapter 1 Introduction
Technical Specifications 1-9
Timing
Derived from three alternative sources:
Internal oscillator
External, from the attached DTE
Receive, derived from the received signal
Diagnostics
Loopbacks
ITU V.54 (V.35 and X.21 only):
Local loopback, activated via management software, or
in V.35 versions by the DTE interface signal
Remote loopback, activated via management software,
or in V.35 versions by the DTE interface signal
Remote loopback at SHDSL repeater
Statistics Collection
SHDSL performance
Indicators
PWR (green)
Power
TEST (red)
Test
SYNC A/B
(green/red)
Synchronization of DSL line
DATA (yellow)
Data Transfer
ALM (red)
Alarm
Physical
Height
43.7 mm / 1.7 in
Width
217 mm / 8.54 in
Depth
170 mm / 6.7 in
Weight
0.5 kg / 1.1 lb
Power Source
AC/DC Voltage
Wide range power supply:
100–240 VAC or -40/60 VDC
Power Consumption
2-wire: 6W max
4-wire: 8W max
Environment
Temperature
0–50°C / 32–122°F
Humidity
Up to 90%, non–condensing