Quick Start Guide ASMi-52L Installation and Operation Manual
2 Configuring ASMi-52L
Configuring the Master Clock
To configure the master clock:
From the System Configuration menu (Main menu > Configuration >
System Configuration > Master Clock), configure the central ASMi-52L clock
to external or internal and remote ASMi-52L clock to the receive clock.
Configuring the SHDSL Interface
To configure the SHDSL interface:
From the SHDSL Configuration menu (Main menu > Configuration > Port
Configuration > SHDSL Configuration), configure the following SHDSL
parameters:
SHDSL compatibility
Power backoff
Snext margin, if line probing is set to adaptive
Current margin, if line probing is set to adaptive
Power spectral density (for ASMi-52L with 2-wire line interface and line
probing set to fixed).
Line probing
Line type (for 4-wire ASMi-52L units only)
Loop attenuation threshold
SNR margin threshold.
Configuring the DTE Interface
ASMi-52L includes a serial or 10/100BaseT DTE interface.
Configuring the Serial Interface
To configure the serial interface:
From the DTE Port Configuration (Main menu > Configuration > Port
Configuration > DTE Configuration), select the required data rate.
Configuring the 10/100BaseT Interface
To configure 10/100BaseT parameters:
1. From the LAN Configuration menu (Main menu > Configuration > LAN
Configuration), configure the following LAN parameters:
Operation mode
Bridge static table
Aging timeout
LAN rate.
For units with the four port integrated switch, configure the parameters one time.
2. Configure the Autonegotiation per port
3. Configure the Max Advertised Capability per port.