Specifications

Installation and Operation Manual Appendix B Parameter List
ASMi-52CQ Ver. 2.12 Configure Transmission Parameters B-9
Table
B-5. Modem Setup: Line Parameters
Parameter Type Use Value Indication
MODEM NAME Read Identifies the modem
type which status is
being viewed or
modified
ASMi-52CQ
ASMi-52
ASMi-52CQ
Standalone ASMi-52 modem
SELECT MODEM Write Selects the modem,
whose operational
parameters are set
MODEM1 LOCAL
MODEM2 LOCAL
MODEM3 LOCAL
MODEM4 LOCAL
Operational parameters are set
for one of the local modems
installed in the LRS-24 chassis
MODEM1 REMOTE
MODEM2 REMOTE
MODEM3 REMOTE
MODEM4 REMOTE
Operational parameters are set
for one of the remote modems
MODEM STATUS Read Displays the modem
configuration control
status
MASTER
PERMANENT
N/A
POWER BACKOFF Write Determines whether
to use the transmitted
power backoff
Enable Enable transmitted power
backoff
Disable Disable transmitted power
backoff
SNEXT MARGIN Write Selects the minimum
desired target margin
with a worst case self
next noise model
given current loop
insertion (49 SHDSL
next is considered the
worst case)
Available only if the
rate adaptation is
enabled (see line
probing configuration
below)
Integer between -
10 and 10
Select Snext margin value
Disable Disable Snext margin
Allows the use of all line rates,
regardless of line condition
CURRENT MARGIN Write Selects the minimum
desired target margin
for the local line
conditions during the
startup sequence.
Available only if the
rate adaptation is
enabled (see line
probing configuration
below)
Integer between -
10 and 10
Select current margin value
Disable Current margin disabled
Allows the use of all line rates,
regardless of line condition