Specifications

Installation and Operation Manual Appendix B Parameter List
ASMi-52CQ Ver. 2.12 Configure Transmission Parameters B-7
Parameter Type Use Value Indication
TS Write Assigns each timeslot to
carry data
DATA
NOT_CONNECT
TS0 may be looped or
transparent:
Looped: TS0 is sent back to
the E1 interface, when
operating opposite remote
units with a serial data
interface.
Transparent: TS0 is
transmitted to the remote
modem.
With G732S transparent
framing, TS0 is always
transparent and TS16 is always
connected.
When operating opposite an
ASMi-52CQ with V.35
interface, assign at least six
timeslots, including timeslot 0
to carry data.
Unit Identical Set Write Copies Sync Mode, Time
Slot Assignment and
Idle Code definitions to
remote modem
YES Copies parameters to the
remote modem
NO Parameters must be defined in
both modems individually
Table
B-4. Modem Setup: T1 Parameters
Parameter Type Use Value Indication
MODEM NAME Read Identifies the modem
type whose status is
being viewed or
modified
ASMi-52CQ
ASMi-52
Master ASMi-52CQ
Standalone ASMi-52 modem
MODEM STATUS Read Displays the modem
configuration control
status
MASTER
PERMANENT
N/A
FRAME MODE Write Selects the framing
mode
Unframed Stream of bits at 2.048 Mbps
ESF 24 frames per multi-frame
SF 12 frames per multi-frame
LINE CODING Write B8ZS
AMI
B8ZS coding
AMI coding
SYNC Write Selects time required
for the T1 port to
return to normal
operation after sync
loss
CCITT
As per requirements of ITU-T
Rec.G.732
Fast After 1 sec
62411 As per requirements of AT&T
TR-62411 (after 10 secs).