System information

Appendix A Active Alarms RADview-EMS ASMi-52 User’s Manual
A-6 ETH Port Level – Active Alarms
Table A-3. SHDSL Link Port Level Active Alarms (Cont.)
Code Severity Description
17
Major SYNC LOSS LINE A
G.SHDSL line A not synchronized
18
Major SYNC LOSS LINE B
G.SHDSL line B not synchronized
Note: This alarm will only appear if the modem is 4 wire
19
Major MNGMNT IS DOWN
Management between NE an FE down (EOC problem)
21
Major ILLEGAL EXTER CLK
Exernal clock not compatible to clock set by user for DTE (not supported in this
device)
22
Minor CRC ERROR OVER LINE A
Too many CRC errors received on G.SHDSL at line A
50
Major LINE PARAMETERS NOT COMP
Configuration parameters do not correspond, causing a lack of synchronization
between NE and FE
A.3 ETH Port Level – Active Alarms
One active alarm may be displayed at the ETH port level.
Table A-4 lists the active alarm at the ETH port level.
Table A-4. ETH Port Level Active Alarm
Code Severity Description
8
Major LAN NOT CONNECTED
LAN not connected (for Ethernet interfaces)