System information

Appendix A Active Alarms RADview-EMS ASMi-52 User’s Manual
A-4 Modem Level – Active Alarms
Table A-1. Modem Level Active Alarms: Modem and Port Levels Combined (Cont.)
Code Severity Description
51
Major EXTERNAL TO INTERNAL CLOCK
Clock missing at the external clock source
60
Major SELF TEST ERROR
Failure occurred while testing the device hardware components
61
Warning SOFTWARE DOWNLOAD
Device currently performing software download
62
Major PS1 Fail
Failure occurred in PS 1
63
Major PS2 Fail
Failure occurred in PS 2
64
Major FAN1 FAIL
Failure occurred in FAN 1
65
Major FAN2 FAIL
Failure in FAN 2 occurred
66
Major OVER TEMPERATURE
Device temperature exceeded maximum range
Modem Level
Table A-2 lists the active alarms at the modem level only.
Table A-2. Modem Level Active Alarms: Modem Level
Code Severity Description
1
Major SELF TEST ERROR
Failure occurred while testing the port hardware components
2
Warning SOFTWARE DOWNLOAD
Port currently performing software download
20
Major ILLEGAL EXTER CLK
Exernal clock not compatible to clock set by user for DTE (not supported in this
device)
23
Major NO DTE INTERFACE
Device lacks a DTE interface
42
Major WIRE MODE NOT COMP
Line interface types (2 wire and 4 wire) for local and remote units do not
corrrespond
43
Major SPAN IS NOT FULL
Span containing information on central office, customer premises equipment,
and repeaters is experiencing a problem on one of its segments
51
Major EXTERNAL TO INTERNAL CLOCK
Clock missing at the external clock source
60
Major SELF TEST ERROR
Failure occurred while testing the device hardware components