System information

Modem Level – Active Alarms A-1
Appendix A
Active Alarms
This appendix lists the active alarms for ASMi-52 fault management at the modem,
port, and repeater levels.
A.1 Modem Level – Active Alarms
At the modem level, active alarms may be displayed at the modem and port levels
combined, or at the modem level alone.
Modem and Port Levels
Table A-1 lists the active alarms at the modem and port levels combined.
Table A-1. Modem Level Active Alarms: Modem and Port Levels Combined
Code Severity Description
1
Major SELF TEST ERROR
Failure occurred while testing the port hardware components
2
Warning SOFTWARE DOWNLOAD
Port currently performing software download
3
Warning INBAND LOOP
Inband-activated loopback in progress
4
Warning LLB FROM DTE
Local loopback activated by physical connector
Note: This alarm will only appear if the V.35 or RS-530 interface is present
5
Warning RLB FROM DTE
Remote loopback activated by physical connector
Note: This alarm will only appear if the V.35 or RS-530 interface is present
6
Major PROP PROT FAIL
RAD proprietary protocol between devices failed
7
Major E1 TS NUM NOT COMP
LRSi card not supported in this device
8
Major LAN NOT CONNECTED
LAN not connected (for Ethernet interfaces)
9
Minor LOOP ATTN. OVER LINE A
Loop attenuation exceeded alarm threshold at line A
10
Minor LOOP ATTN. OVER LINE B
Loop attenuation exceeded alarm threshold at line B