System information
RADview-EMS ASMi-52 User’s Manual Chapter 3 Configuration Management
Repeater Level – Diagnostics Menu 3-35
Resetting the Repeater Network Side
The Reset Network Side command enables you to reset the repeater network
side.
To reset the repeater network side:
1. In the RADview ASMi-52 window, select one of the three repeaters.
2. Select Configuration > Reset Network Side.
The repeater network side is reset.
3.11 Repeater Level – Diagnostics Menu
The repeater level Diagnostics menu allows you to test repeater diagnostics.
Figure 3-34. Repeater Level Diagnostics Menu
Testing the Repeater Diagnostics
The Test command enables you to test the repeater diagnostics.
To test the repeater diagnostics:
• At the repeater level, select Diagnostics > Test…
Figure 3-35. Repeater Test Dialog Box
Table 3-26. Repeater Test Parameters
Parameter Possible Values / Remarks
Repeater
1…8
Repeater Side
Network
Note: This field is read-only
Current Test
None, RLB