System information

RADview-EMS ASMi-52 User’s Manual Chapter 3 Configuration Management
E1 and T1 Port Levels – Configuration Menu 3-29
Configuring the Parameters for the T1 Port
The Parameters command enables you to configure the T1 port parameters.
To configure the parameters for the T1 port:
1. At the T1 port level, select Configuration > Parameters…
2. Configure the desired parameters and click <Set>.
Table 3-22. Port Parameters
Parameter Possible Values / Remarks
Location Near-End, Far-End
SHDSL Mode STU-C, STU-R
Port CONTROL, ETH, SHDSL Link, E1, T1, DTE (V.35, X.21, RS-530)
Far-End Modem
Type
Unknown, ASMi-52, ASMi-52 Master, ASMi-52 Slave, ASMi-52/CD, ASMi-52/CQ,
LRS-52, FCD-IP, FCD-IPM, D8SL, MP-SHDSL
Line Type The line type of the T1 port
Unframed, ESF, D4 (SF)
Line Code The line code of the T1 port
B8ZS, AMI
Rx Gain The Rx gain of the T1 port
Short Haul, Long Haul
Line Mode The line mode of the T1 port
CSU, DSU
Tx Gain (dB) The Tx gain of the T1 port
7.5, 15.0, 22.5
Note: This field is only enabled when the Line Mode value is “CSU”
Line Length (ft)
0-133, 134-266, 267-399, 400-533, 534-655
Note: This field is only enabled when the Line Mode value is “DSU”
Identical Settings Whether the FE settings for the two ends of the T1 port line are the same
No, Yes
Sync Mode The synchronization mode of the T1 port
TR-62411, CCITT, FAST
Idle Code (hex) The idle code of the T1 port
0…FF
Signaling Mode
None, Robbed Bit
Dedicated TS
Configuration
Inband Mng The inband management type of the DTS configuration
None, Dedicated TS/FR
Tx to Remote Disable, Enable
Note: This field is available for the FE modem when it is connected to an E1