System information

RADview-EMS ASMi-52 User’s Manual Chapter 3 Configuration Management
Modem Level – Diagnostics Menu 3-19
Figure 3-19. Test Dialog Box
Table 3-16. Test Parameters
Parameter Possible Values / Remarks
Location
Near-End, Far-End
SHDSL Mode
STU-C, STU-R
Far-End Modem
Type
Unknown, ASMi-52, ASMi-52 Master, ASMi-52 Slave, ASMi-52/CD, ASMi-52/CQ,
LRS-52, FCD-IP, FCD-IPM, D8SL, MP-SHDSL
Current Test The test currently running on the port
Activate Test
None, E1 RLB or T1 RLB, E1 LLB or T1 LLB, IR RLB, IR LLB, E1+IR RLB or T1+IR
RLB, E1+IR LLB or T1+IR LLB, RLB, LLB, BERT, BERT+RLB
Note: Before running a new test, you must click <Stop> to stop the current test
Note: You can only run a new test when the Current Test value is None
Test Duration (min) The amount of time the test will run (in minutes)
Unchecked (Test Duration disabled), Checked (Test Duration enabled)
1…4095
Note: If you insert a value outside the above range, the Status Bar will display an error
message
Test Initiator
None, User, DTE
BERT Pattern
2E15-1, Alternate, Mark, Space
[Stop] Click <Stop> to stop the test
Note: This button is enabled only when the Test Initiator value is User
[Apply] Click <Apply> to run the test
Note: This button is only enabled when no test is currently running on both modems or
if BERT is running on the FE modem and BERT is selected for the NE modem.
[Close] Click <Close> to close the Test dialog box
[Refresh] Click <Refresh> to update the Test dialog box