Specifications

RADring
Installation & Operation Manual Operation
3/11/98 12:28 Diagnostics and Troubleshooting 4-3
These modules have PWR, MNG and PORT LEDs. The common set of LED
port conditions utilized by the lobe modules are presented in Table 4-2.
Table 4-2 Lobe Module LED Port Conditions
LED Port Condition Meaning
Continuously ON Station inserted into ring
Continuously OFF Station bypassed
Blinking Port disabled by management
In addition, the active TL-4 modules (TL-4/AU, TL-4/ASU, TL-4/AS,
TL-4/ASD) have 4M and 16M LEDs, indicating data rate configured for
operation. The TL-2/ED modules (TL-2/EDS, TL-2/EDU, TL-2/EDSU) have a
TLR LED, indicating operating mode.
Port LED does not light (station bypassed):
A workstation is automatically bypassed whenever:
It becomes inactive
Its port connector is unplugged
Bit rate mismatching is detected
It receives disable command from RADview Network Management
Check if station is active
Check cable connections between station and lobe.
Make sure that the bit rate is correctly configured.
Do diagnostic test at stations side (TRIC) to see if any malfunction was
recorded.
Blinking Port LED (port disabled by management):
Check at management station to see any events indicating reason for port
disabled.
RI/RO Modules
Ring In/Ring Out Modules consist of the following
TCR
TFR
TIO
TFC