Specifications

RADring
Installation & Operation Manual System Installation
3/11/98 12:29 Connecting Redundant Power Supply 3-7
3.8 Connecting Redundant Power Supply
Basic Module
1. Disconnect all power from the RADring hub and place the hub
up-side-down on a flat surface.
2. Remove the panel covering the opening for the additional power
supply. The cover is held in place by four screws.
3. Connect the Molex connector of the cord attached to the power supply
to the JP2 connector on the mother board.
4. Place the power supply in the opening and align the holes on the power
supply cover with the holes on the unit enclosure.
5. Fasten the cover to the enclosure using the four screws provided in the
installation kit.
6. Attach the rubber feet (provided in the installation kit) to the power
supply cover using the adhesive surface. Affix the rubber feet to match
the positions of the two rubber feet on the enclosure.
Note
Refer to the installation instructions for the first power supply as an example, if
you should experience difficulties following the above procedure.
POWER
SUPPLY
1
MOLEX CONNECTOR
ON HUB (JP2)
POWER
SUPPLY
2
FAN
TIE CONNECTOR
ON MOTHER BOARD
MOLEX
CONNECTOR
HUB
Figure 3-1 Connecting Basic Power Supply Module