Specifications
RADring
Installation & Operation Manual System Installation
3/11/98 12:29 Inserting Module Cards 3-5
Insertion of the CML or CML/NM module is straightforward:
1. Insert the module into the last slot. Check that the component side of
the board faces to the right. Push the module into the slot until it
reaches the end.
2. Press firmly on the module to fully insert it into the connector on the
motherboard.
3. Secure the module by tightening its panel screw.
Caution
Static electricity can severely damage micro-circuits. Avoid contact with
components on the modules, and avoid placing them on metal surfaces.
Table 3-1 Strap Selection
Item Function
DCE-DTE Selector Selects the operating mode of the RS-232/V.24 interface:
DCE - for direct connection to RS-232 port
DTE - for connection via a modem
The three furthest sections to the left of the switch SW1 determine the bit rate
of the RS-232/V.24 interface
Bit Rate Switch Setting
123
2.4K
↓↓↓
Bit Rate Selector 4.8k
↓↓↑
9.6K
↓↑↓
14.4K
↓↑↑
19.2K
↑↓↓
38.4K
↑↓↑
57.6K
↑↑↓
115.2K
↑↑↑
Power Supply Selector Selects the power supply source:
PS1-ON for power supply 1
PS2-ON for power supply 2
AGENT COMM Selector Selects data rates for the out-of-band communication and Parity “ON” or
“OFF”. Parity ”OFF” indicates 10-bit data (id, 1 start, 1 stop).