Installation & Operation Manual System Installation
3/11/98 12:29 Common Logic Module (CML/NM) Setting & Installation 3-3
3.4 Installation of RADring Enclosure
1. Place the RADring hub enclosure in the intended location.
2. Remove blank panels (if existing) from the slots in which the modules are
to be installed
3. Specify on the CML or CML/NM module through switch `selection
which of the two power supply options will be used
4. Check that the Common Logic Module (CML), with or without network
management, is in its proper position; it must be inserted in the very last
slot on the right of the hub.
5. Set the internal jumpers and switches in accordance with the specific
requirements of your installation. Install modules in the enclosure slots as
required by the configuration. See Chapter 5 for module installation
instructions.
6. Prepare and connect the required cabling to the installed modules*.
7. When ready for operation, connect the mains power cord to the
designated power receptacle on the back of the enclosure. The power
receptacle must provide reliable, high quality grounding. After the unit
has been switched on the fan will begin to operate.
8. Initialize LAMP TEST in order to check that all of the indicators are
functioning properly.
Note
If for any reason the FLT of the CML or CML/NM remains lit, turn off the
RADring unit immediately and check that the unit is properly configured.
After power connection, the RADring is ready for operation.
Caution
The RADring protective ground is connected by means of the AC power
cable. The protective ground is essential for safety.
Warning
Before switching on the RADring hub, verify that the protective earth
terminals are connected to the protective connector of the mains cord.
Only insert the mains plug in a socket outlet provided with a protective
earth contact. The protective action must not be negated by use of an
extension cord (power cable) without a protective conductor.
*See Connector Types section for module cable requirements.