Specifications

RADring
Installation & Operation Manual Functional Description
3/11/98 12:33 Power Consumption 2-47
2.12 Power Consumption
The modularity of the RADring allows the use of a wide variety of modules,
each with a different power requirement.
Hub Power
Supply
The power supply of the RADring depends on which option is chosen.
Table 2-1 below indicates the available options and their corresponding
power supplies.
Table 2-1 Available RADring Hub Options and Corresponding Power Supplies
Hub Maximum
Power Supply
Maximum
Current
Voltage
RR-HUB 65W 11.8A 5.5V
RR-HUB/RDNT 65W + 65W 11.8A 5.5V
RR-HUB/HP 125W 22.7A 5.5V
Module Power
Requirements
Table 2-2 below indicates the maximum power consumption of the
modules
Table 2-2 Maximum Power Consumption
Module Maximum Power
Consumption
TL-2/EDU /EDS 0.2A
TL-2/F 0.5A
TL-4/S /U /SD /SU 0.2A
TL-4/AS /ASD /AU /ASU 1.2A
TL-4/CX 0.35A
TIO 0.06A
TFC1 0.35A
TFC2 0.5A
TFR 0.65A
TCR 0.55A
TJA 0.55A
CML/NM 0.15A
CML/IB 1.0A
CML/IB-E 0.5A
EP-8T 0.6A
EP-4T/AUI 2.5A