- RAD Data Communications Modem User's Manual
ASMi-450 Control from the Control Port
ASMi-450 Installation and Operation Manual 4-29
4.7 Configuration Error Messages
The ASMi-450 provides configuration error messages for the control terminal
user. The configuration messages have the format ERROR, followed by a two-
digit code. The ASMi-450 will display a short description of the error message
after the ERROR code.
The error messages are explained below.
ERROR 01 ILLEGAL LOOP COMBINATION
Illegal combination of loopbacks: you are trying to activate simultaneously
local and remote loopbacks. Only one loopback can be connected at a time.
ERROR 02 REM REM LOOP WHILE SYNC LOSS
You are trying to activate REM REM loopback while synchronization is lost.
ERROR 03 ILLEGAL CLOCK MODE ON REMOTE SIDE
You are trying to select the internal clock mode at the remote side.
ERROR 04 LOOP IS NOT ACTIVE
You are trying to disconnect a loopback that is not active.
ERROR 06 ILLEGAL NODE NUMBER
You are trying to select a node number greater than 255.