- RAD Data Communications Modem User's Manual

ASMi-450 Control from the Control Port
4-14 ASMi-450 Installation and Operation Manual
Notes
In addition to the parameters listed in Section 3-5, the following parameters can
be programmed only from the terminal:
PWD Password protection: select YES or NO
LOG_OFF Idle disconnect time:
NO automatic session disconnection disabled.
10_MIN automatic disconnection after ten minutes if no input
data is received by the ASMi-450.
CTS Determines CTS state:
ON The CTS line is always ON (active).
=RTS The CTS line follows the RTS line.
DCD_DEL With ASMi-450 control port defined as DTE, indicates delay (in
msec) between DCD=ON and the sending of data.
Values: 0, 10, 50, 100, 200, 300 msec.
POP_ALM Controls the automatic display of alarms in the terminal
YES The terminal automatically displays every 10
minutes the alarm status (or whenever an alarm
changes state to ON)
NO The automatic display feature is disabled
DSR Determines the DSR state:
ON The DSR line is continuously on. It will switch to
OFF for five seconds after the DTR line is switched OFF.
DTR The DSR line tracks the DTR line. When
INTERFACE=DTE, the DSR line will switch to ON
for five seconds when the RI line is ON while the
DTR line is OFF.
AUXILIARY Selects the management mode supported by the control port of
DEVICE the ASMi-450:
TERMINAL management by means of a supervision terminal.
NMS_SLIP management by means of Telnet host, or an
SNMP network management station.
6. After the desired parameter values are selected, press <CR> to end. The ASMi-450
will display the TIME and DATE fields, followed by the ASMi-450 prompt.