- RAD Data Communications Modem User's Manual

Quick-Start Guide
Quick-Start Guide - 2 ASMi-450 Installation and Operation Manual
2. Configuration Procedure
You are ready to start ASMi-450 configuration. After typing a command, press
<CR> to see the data entry form:
Use the space bar to move the cursor to the desired field.
Use the F key to scroll forward, and the B key to scroll backward among the
available values. For free text fields, type the desired text.
When ready, press <CR> to display the next data entry page of the current
command. Pressing<CR> after the last data entry, executes the command.
You can exit without executing the changes by pressing CTRL-C at any
time before pressing <CR>.
To obtain correct display of data forms on your terminal, you must select the
terminal control sequences:
1. Type the command F.
2. In each field, type the code corresponding to your terminal type. The chart
below lists the codes for common terminal types:
Terminal Type
TV920 VT52 VT100 Freedom 100/110 Freedom 220
Clear Screen 1B2A0000 N/A 1B5B324A 1B2A0000 1B5B324A
Cursor Home 1E000000 1B480000 1B5B4800 1E000000 1B5B4800
Cursor Right 0C000000 1B430000 1B5B3143 0C000000 1B5B0143
3. When done, press <CR>.
Configure the ASMi-450 in the following order:
Step Action Use the Command
1 Set ASMi-450 system time
TIME
2 Set ASMi-450 system date
DATE
3 Define control port characteristics
DEF SP
4 Define system characteristics
DEF SYS
5 Define general system parameters
DEF AGENT
DEF NAME
DEF NODE
DEF PWD
Function