Specifications

Appendix C IR-IP Interface Module Installation and Operation Manual
C-4 IR-IP Management Subsystem, General ASMi-31 Ver. 3.0
Table C-3. RJ-45 Pinout
Pin Name Function
1 TD (+)
Transmit data (positive)
2 TD (-)
Transmit data (negative)
3 RD (+)
Receive data (positive)
6 RD (-)
Receive data (negative)
C.4 Preliminary Configuration of ASMi-31 with IR-IP
Before starting configuration of the IR-IP interface module, make sure to set the
following jumpers of the local and remote units as detailed below:
RLB jumper (JP14) – DIS
LLB jumper (JP15) – DIS
Section 6 (DCD) of the SW6 DIP switch – ON
Section 7 (DSR) of the SW6 DIP switch – ON.
C.5 IR-IP Management Subsystem, General
Introduction
The IR-IP interface module management subsystem supports the following
functions:
Preliminary configuration
Configuration of management access parameters
Advanced configuration of IR-IP parameters
Collection and display of statistical performance data
Maintenance functions, which include:
Software downloading
Resetting of various subsystems
Display of error log
Ping utility, for checking IP connectivity.
The management subsystem of the IR-IP interface module is a separate,
independent entity.
The communication with the IR-IP management subsystem is made through the
local LAN interface connector of the IR-IP module, designated 10BASE-T, using
the Telnet protocol. Passwords can be used to prevent unauthorized access.