Specifications
ASMi-31 Installation and Operation Manual Appendix B IR-ETH Interface Module
Installation and Operation B-3
B.3 Installation and Operation
Figure B-3
shows the IR-ETH layout, the locations of the DIP switch, and the rear
panel components for the UTP version.
1
2
3
4
Figure B-3. IR-ETH Module Layout (UTP Option)
Setting the DIP Switch
Set the IR-ETH DIP switch according to
Table B-2
.
Table B-2. DIP Switch Settings
Switch Number Name Description (Default setting in bold)
1 SQ/FD On – Ethernet full-duplex mode
Off – Ethernet half-duplex mode
Note: The SQ/FD switch is not used in the Ethernet bridge with the BNC connector option.
2 CMP On – Strips padding bits inserted in 64-byte frame
Off – Transmits frames over WAN as is
3 FIL On – Passes only frames destined for another LAN
Off – Disables LAN filter, passes all frames transparently