Specifications

Installation and Operation Manual Chapter 5 Troubleshooting and Diagnostics
ASMi-31 Ver. 3.0 Handling Alarms 5-3
5.2 Handling Alarms
ASMi-31 contains a buffer which stores the system alarms. When a record of an
alarm, or several alarms are stored in the alarm buffer, the ALM LED indicator
turns ON. Once the alarm buffer is cleared, the ALM LED turns OFF.
To display the alarm buffer contents:
1. Press the CURSOR button to move the cursor to the Menu Type field.
2. Press the SCROLL button until ALARM BUFFER is displayed.
3. Press the CURSOR button to move the cursor to the LOC/REM field.
4. Press the SCROLL button to toggle between the local and the remote modem.
If management is not active, REM (remote modem) will not be displayed.
5. Press the CURSOR button to move to the Menu Options field.
6. Press the SCROLL button to display alarms stored in the buffer (see
Figure 5-1
).
ALARM BUFFER
LOC
NO MANAGEMENT
NO MANAGEMENT
SYNC LOSS
ILLEGAL EXT CLOCK
CONFIG MISMATCH
NVRAM FAILED
NO INTERFACE
REM
LOC
Figure 5-1. Displaying Alarms
Table 5-1. ASMi-31 Alarms
Alarm Description
NO MANAGEMENT Management channel is not available.
SYNC LOSS The synchronization between the modems is lost.
ILLEGAL EXT CLK The clock rate detected by the modem is not supported by the
modem.
CONFIG MISMATCH There is a mismatch between the line configurations of both
modems.