Specifications

Chapter 4 Configuration Installation and Operation Manual
4-10 Matching the Line and DTE Settings of the Modems ASMi-31 Ver. 3.0
To configure RLB option:
1. Press the CURSOR button to move the cursor to the Menu Type field.
2. Press the SCROLL button until DTE CONFIG is displayed (see
Figure 4-11
).
3. Press the CURSOR button to move the cursor to the LOC/REM field.
4. Press the SCROLL button to select the local modem or the remote modem.
5. Press the CURSOR button to move the cursor to the Menu Options field.
6. Press the SCROLL button until RLB is displayed.
7. Press the CURSOR button to move the cursor to the Parameters field.
8. Use the SCROLL button to toggle between ENABLE and DISABLE and press the
ENTER button to set your choice.
When an RLB test is initiated by the DTE, the LINE STATUS, TEST menu
displays DTE>RLB in the Parameters field. While this test is running, the LINE
CONFIG menu and the TEST menu are masked, line parameters cannot be
modified, and no other tests can be initiated. The DTE>RLB test performance
will end if the RLB option is disabled, or if the DTE ends the test request.
When the test is stopped, line parameters can be modified again and other
tests can be initiated.
MODE
FORMAT
DATARATE
CNT SIG-DCD
CNT SIG-DSR
RLB
LLB
DTE CONFIG
*ENABLE
ENABLE
RLB
DISABLE
Figure 4-11. Configuring RLB Option
4.4 Matching the Line and DTE Settings of the
Modems
If a mismatch in the line or DTE configuration parameters of the local and remote
modems is detected, ASMi-31 initiates a CONFIG MISMATCH alarm
(see
Figure 4-12
) and activates the CONFIG MATCHING menu. This option enables
you to configure both modems with the same parameters, which were stored in
one of them (user’s choice) the last time it was used.