Specifications

Chapter 4 Configuration Installation and Operation Manual
4-2 Configuring Line Parameters ASMi-31 Ver. 3.0
4.2 Configuring Line Parameters
Menu options are selected by the three front-panel buttons and displayed on the
LCD display. Functions of the buttons are described in
Chapter 3
.
The LINE CONFIG menu allows you to configure the line parameters. You can
configure both the local modem and the remote modem, provided that both
modems are connected and the management is active.
When
you configure a parameter, when both modems are connected and the
management is active, the message “WAIT...” is displayed while the local modem
sends the new settings to the remote modem and receives an acknowledgment.
Once the acknowledgment is received, the message disappears and the new
setting is displayed with an asterisk next to it. If only the local modem is
connected, or the management is not active, you can configure only the local
modem. In such a case, the message LOC CONFIG ONLY will be displayed on the
LCD for a short period for each parameter you set.
If, at the time you try to configure the system, the party on the other side of the
line is already modifying the configuration, the message “U R BEING CONFIG” will
appear on the LCD and you will not be able to modify the system. You will only be
able to modify the configuration after the other party has finished its
modifications and:
A minute has passed since the other party finished and the system returns
back to LINE STATUS.
or
The other party scrolled out of LINE CONFIG menu.
The following line parameters are available for configuration:
Clock type
Rate adaptation mode.
Selecting the Clock Type
You must select the clock mode for both local and remote modem.
To select the clock type:
1. Press the CURSOR button to move to the cursor to the Menu Type field.
2. Press the SCROLL button until LINE CONFIG is displayed (see
Figure 4-2
).
3. Press the CURSOR button to move the cursor to the Menu Options field.
4. Press the SCROLL button until CLKTYPE is displayed (see
Figure 4-3
).
5. Press the CURSOR button to move the cursor to the Parameters field.
6. Press the SCROLL button to display the desired clock type (INT RCV, EXT RCV,
RCV INT, or RCV EXT). The left column refers to the settings of the local
modem, and the right column refers to the settings of the remote modem).
7. Press the ENTER button to set your choice.