Specifications

Installation and Operation Manual Chapter 3 Operation
ASMi-31 Ver. 3.0 ASMi-31 Default Settings 3-3
Table 3-2. ASMi-31 Indicator Status
Indicator Status
PWR On
LCD Display Displays opening screen:
“ASMi-31 REV x.x
I N I T I A L I Z I N G...”
SYNC Red
TST Off
TD Depends on DTE data transmission.
RD Off
RTS Depends on DTE RTS signal status.
DCD Off
3.3 ASMi-31 Default Settings
Table 3-3
and
Table 3-4
list default values of the line and DTE parameters.
Table 3-3. Line Parameters
Parameter Default Value
CLKTYPE INT RCV
ADAPT RAD PROP
Table 3-4. DTE Parameters
Parameter Default Value
LLB ENABLE*
RLB ENABLE*
MODE SYNC
DATARATE 64K
CNT SIG-DCD SW
CNT SIG-DSR SW
For ASMi-31 with X.21, G.703 Codirectional and Ethernet DTE interfaces, the LLB
and RLB default values are always set to DISABLE because these interfaces do not
support loopback activation via DTE connector pins.
Note