Specifications
Chapter 1 Introduction Installation and Operation Manual
1-6 Functional Description ASMi-31 Ver. 3.0
1.3 Functional Description
This section contains functional descriptions of the ASMi-31 circuit blocks, shown
in
Figure 1-3
.
PLL
CPU
68032
Data & Add Bus
External Clock
Master
Clock
Digital
Interface
LCD
Line
Power
Overvoltage
Protection
Power
Supply
Hybrid Echo
Cancellation
Memory
PEB - 2070
IOM-2
U-Interface
Data
Data
LCD LEDs
BERT
Figure 1-3. ASMi-31 Block Diagram
• Digital interface – An interchangeable module which translates the received
and transmitted data from TTL levels to any combination of DTE interfaces
supported by the modem.
• CPU MC68302 – This processor handles the following functions:
Derive command information from and to management channel via
D-channel to change the status and the configuration of the remote unit
(ASMi-31).
Handle the serial bus protocol for the U-interface.
Monitor and command.
Activate and deactivate alarms and diagnostics signals.
Receive data incoming from the DTE interface, either encapsulated or
rate adapted (for rates lower than 64 kbps), and send the data by serial
bus to the U-interface. Compute the same in the reverse direction.
Drive LEDs to indicate status and failure conditions.
Read and carry out command signals arriving from the DTE interface.