Installation and Operation Manual ASM-61 2-Wire Symmetric VDSL-Based Modem Version 1.
ASM-61 2-Wire Symmetric VDSL-Based Modem Version 1.0 Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communications Ltd. ("RAD"). No part of this publication may be reproduced in any form whatsoever without prior written approval by RAD Data Communications.
Limited Warranty RAD warrants to DISTRIBUTOR that the hardware in the ASM-61 to be delivered hereunder shall be free of defects in material and workmanship under normal use and service for a period of twelve (12) months following the date of shipment to DISTRIBUTOR.
General Safety Instructions The following instructions serve as a general guide for the safe installation and operation of telecommunications products. Additional instructions, if applicable, are included inside the manual. Safety Symbols Warning This symbol may appear on the equipment or in the text. It indicates potential safety hazards regarding product operation or maintenance to operator or service personnel.
Handling Energized Products General Safety Practices Do not touch or tamper with the power supply when the power cord is connected. Line voltages may be present inside certain products even when the power switch (if installed) is in the OFF position or a fuse is blown. For DC-powered products, although the voltages levels are usually not hazardous, energy hazards may still exist.
Connection of Data and Telecommunications Cables Data and telecommunication interfaces are classified according to their safety status. The following table lists the status of several standard interfaces. If the status of a given port differs from the standard one, a notice will be given in the manual. Ports Safety Status V.11, V.28, V.35, V.36, RS-530, X.
Caution Attention To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cords. Pour réduire les risques s’incendie, utiliser seulement des conducteurs de télécommunications 26 AWG ou de section supérieure. Some ports are suitable for connection to intra-building or non-exposed wiring or cabling only. In such cases, a notice will be given in the installation instructions. Do not attempt to tamper with any carrier-provided equipment or connection hardware.
Canadian Emission Requirements This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulation. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Warning per EN 55022 (CISPR-22) Warning This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user will be required to take adequate measures.
Declaration of Conformity Manufacturer's Name: RAD Data Communications Ltd. Manufacturer's Address: 24 Raoul Wallenberg St. Tel Aviv 69719 Israel declares that the product: ASM-61 Product Name: conforms to the following standard(s) or other normative document(s): EMC: Safety: EN 55022: 1998 Information technology equipment, radio disturbance characteristics, limits and methods of measurement.
Contents Chapter 1. Introduction 1.1 Overview..................................................................................................................... 1-1 Product Options ................................................................................................................... 1-1 Application ........................................................................................................................... 1-1 Features.............................................................
Table of Contents ii Installation and Operation Manual ASM-61 Ver. 1.
Chapter 1 Introduction 1.1 Overview ASM-61 is a dedicated carrier-class VDSL (Very High-bitrate Digital Subscriber Line) modem operating at symmetrical line rate of 10 Mbps. ASM-61 serves for transporting 10/100BaseT Ethernet traffic over 2-wire line using VDSL technology. Product Options ASM-61 always operates in pairs: • ASM-61/CO, for the central office deployment • ASM-61/CPE, for customer premises deployment.
Chapter 1 Introduction Installation and Operation Manual Table 1-1. Line Attenuation Cable Type Attenuation [dB] PIC 0.4 mm/26 AWG -66.0 PIC 0.5 mm/24 AWG -53.0 PE 0.4 mm/26 AWG -64.2 PE 0.5 mm/24 AWG -50.0 PE 0.63 mm/22 AWG -41.4 PE 0.9 mm/19 AWG -29.1 FP 1.14 mm -49.7 CAT-3 -71.5 CAT-5 -50.0 DTE Interface The ASM-61 DTE interface is an Ethernet/Fast Ethernet port with VLAN support.
Installation and Operation Manual 1.2 Chapter 1 Introduction Physical Description Figure 1-2 shows a 3D view of the ASM-61 standalone modem. Figure 1-2. 3D View of ASM-61 The front panel includes three LEDs, which display the status of power, line synchronization status and LAN activity status. For detailed description of the front panel, see Chapter 3. The rear panel includes power connector, LAN interface connectors and a line connector.
Chapter 1 Introduction Installation and Operation Manual The modem consists of the following major modules: • Ethernet Block includes an external Ethernet component configured as a single PHY and connected in one end at LAN interface by passive components and to the second end to a standard Ethernet device acting as MAC (Media Access Controller). By autonegotiation procedure each MAC can configure its Ethernet PHY independently of the remote site.
Installation and Operation Manual Chapter 1 Introduction Line Attenuation See Table 1-1 Power Spectral Density -58 dBm/Hz to -98 dBm/Hz, as per ETSI TS 1012701 requirements Spectral Placement Downstream: 0.9 MHz to 3.5 MHz Upstream: 4 MHz to 7.9 MHz Connector RJ-45; pin 4 and pin 5 Network Topology Ethernet extension Port One 10/100 Mbps LAN Autonegotiation Always enabled (for appropriate configuration mode) Standard IEEE 802.3, IEEE 802.
Chapter 1 Introduction 1-6 Technical Specifications Installation and Operation Manual ASM-61 Ver. 1.
Chapter 2 Installation This chapter describes installation and setup procedures for the standalone ASM-61 modem. After installing the unit, refer to Chapter 3 for the operating instructions. Warning Note Internal settings, adjustment, maintenance, and repairs may be performed only by a skilled technician who is aware of the hazards involved. Always observe standard safety precautions during installation, operation, and maintenance of this product.
Chapter 2 Installation Installation and Operation Manual 2.3 Installation and Setup ASM-61 is delivered completely assembled. It is designed for tabletop, wall or 19-inch rack installation. The ASM-61/CO units are installed at the central site, ASM-61/CPE units are installed at the remote site. To install an ASM-61 unit: 1. Connect the line (see Connecting the Line below). 2. Connect the DTE (see Connecting the DTE below). 3. Connect power to the unit (see Connecting the Power below).
Installation and Operation Manual Chapter 2 Installation Table 2-1. 10/100BASE-T Connector Pinout Pin Signal 1 Rx + 2 Rx - 3 Tx + 4 – 5 – 6 Tx - 7 – 8 – Connecting the Power Warning Before switching on this unit and connecting or disconnecting any other cable, the protective earth terminals of this unit must be connected to the protective ground conductor of the power cord. If you are using an extension cord (power cable) make sure it is grounded as well.
Chapter 2 Installation 2-4 Installation and Setup Installation and Operation Manual ASM-61 Ver. 1.
Chapter 3 Operation This chapter provides the description of the ASM-61 front-panel indicators, and details the modem's operating procedures (turn-on, front-panel indications, performance monitoring and turn-off). Installation procedures given in Chapter 2 must be completed and checked before attempting to operate ASM-61. 3.1 Front Panel Indicators The front panel of ASM-61 includes three LED indicators that show the current operating status of the unit. Figure 3-1 shows the ASM-61 front panel.
Chapter 3 Operation 3.2 Installation and Operation Manual Operating ASM-61 Turning On ASM-61 ASM-61 is turned on as soon as the power is connected to the unit. The PWR indicator lights up and remains lit as long as ASM-61 receives power. Normal Operation Always operate ASM-61 in pairs: ASM-61/CO opposite ASM-61/CPE. ASM-61 units operate with the constant line rate (10 Mbps) and preset timing modes (ASM-61/CO – internal, ASM-61/CPE – received).
24 Raoul Wallenberg St., Tel Aviv 69719, Israel Tel: +972-3-6458181, Fax: +972-3-6483331, +972-3-6498250 E-mail: erika_y@rad.com, Web site: www.rad.com Customer Response Form RAD Data Communications would like your help in improving its product documentation. Please complete and return this form by mail or by fax or send us an e-mail with your comments.
Error Report Type of Error(s) ❒ Incompatibility with product or Problem(s): ❒ Difficulty in understanding text ❒ Regulatory information (Safety, Compliance, Warnings, etc.) ❒ Difficulty in finding needed information ❒ Missing information ❒ Illogical flow of information ❒ Style (spelling, grammar, references, etc.) ❒ Appearance ❒ Other _________ Please list the exact page numbers with the error(s), detail the errors you found (information missing, unclear or inadequately explained, etc.
www.rad.com INTERNATIONAL HEADQUARTERS: 24 Raoul Wallenberg Street, Tel Aviv 69719, Israel, Tel: 972-3-6458181 Fax: 972-3-6498250, 972-3-6474436, Email: market@rad.com NORTH AMERICA HEADQUARTERS: 900 Corporate Drive, Mahwah, N.J. 07430, Tel: (201) 529-1100 Toll Free: 1-800-444-7234, Fax: (201) 529-5777, Email: market@radusa.com Publication No.