Specifications
Installation and Operation Manual Chapter 2 Installation and Setup
AMC-101 Installing AMC-101 2-3
Power Supply
AC
Alarm Relay
Connector
GND
JP7
VCC
IDLE_EN
Interface
Module
Interface
Module
LEDs Card
JP2
Alarm Relay
Card
Figure 2-1. PCB Layout
Table 2-1. Jumper Settings
Jumper Description Settings (Default settings in bold)
JP2 If illegal combination of card types and selected data
rate is detected, CONFIG alarm is relayed and FLT LED
blinks
If illegal combination of card types and selected data
rate is detected, CONFIG alarm is masked and FLT LED
remains OFF
Jumper installed
Jumper not installed
JP7 If no signal is received from the other side, idle signal is
transmitted
If no signal is received from the other side, idle signal is
not transmitted
Jumper installed
Jumper not installed
Installing Interface Modules
AMC-101 interface modules are hot-swappable, that means they can be replaced
when the unit is ON.
To install an interface module:
1. Slide the module into appropriate slot.
2. Fasten the two front panel screws to secure the module to the AMC-101
frame.