Specifications

Chapter 1 Introduction Installation and Operation Manual
1-4 Overview AMC-101
Table 1-2. Electrical Interface Modules
Typical Range (Attenuation) Impedance
Retimed
Mode
Transparent
Mode
Module
Name
Retimed/
Transparent
Protocols
Supported
Cable
Type
Connector
Type
[]
[m] [ft] [m] [ft]
AMC-M/UTP/155 R/T STS-3c UTP Cat 5 Shielded RJ-45 100 100 328 50 164
AMC-M/STP/155 R/T STS-3c STP Type 1 DB-9 150 100 328 50 164
AMC-M/UTP/100 R/T FDDI UTP Cat 5 Shielded RJ-45 100 100 328 50 164
AMC-M/10BT/B* R Ethernet UTP Cat 5 Shielded RJ-45 100 100 328
AMC-M/CX/BNC/155 R
STS-3c,
STM-1
Coax BNC 75 12.7 dB**
AMC-M/CX/DIN/155 R
STS-3c,
STM-1
Coax
DIN 47295
1.6/5.6 coax
75 12.7 dB**
The AMC-M/10BT/B modules require the modules of the same type installed at
the local and remote sites of the application (AMC-101 only).
135m range of the AMC-M/CX/BNC/155 and AMC-M/CX/DIN/155 is attainable
when using RG-59 B/U (at 78 MHz, in accordance with the square root of
frequency law).
Controls
AMC-101 includes a rate selector for retimed modules (51, 100, 155 Mbps). For
transparent modules, the rate selector is set to the OTHER position.
If the rate selector is set to OTHER, retimed modules operate in transparent mode.
Diagnostics
AMC-101 supports activation of simultaneous loopbacks towards the user and
network sides. The loopbacks are activated via a front panel WRAP pushbutton.
Alarm Relay
AMC-101 includes a D-type 9-pin dry contact female connector, which serves for
relaying major and minor alarms.
Compliance
AMC-101 operation complies with ATM Forum and ITU-T G.957 and G.958
specifications.
Notes
Note