- RAD Data Communications TV Converter Box User's Manual

Chapter 2 - Installation & Setup AMC-101
Installation & Operation Manual
2-30 AMC-101 Modules
UTP/155/T Module
Figure 2-31 UTP/155/T Module Front Panel
Connector: Shielded RJ-45
Used with: UTP Cat 5
Protocols supported: STS-3c
Timing mode: Transparent
Coding method: NRZ
Range: 50 m
Impedance:
100
Table 2-4 UTP/155/T Pinout
Pinout
Pin 1 Tx+
Pin 2 Tx-
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7 Rx+
Pin 8 Rx-