AMC-101 Universal Media Converter and Repeater Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communications. No part of this publication may be reproduced in any form whatsoever without prior written approval by RAD Data Communications. No representation or warranties for fitness for any purpose other than what is specifically mentioned in this manual is made either by RAD Data Communications or its agents.
Warranty This RAD product is warranted against defects in material and workmanship for a period of one year from date of shipment. During the warranty period, RAD will, at its option, either repair or replace products which prove to be defective. For warranty service or repair, this product must be returned to a service facility designated by RAD. Buyer shall prepay shipping charges to RAD and RAD shall pay shipping charges to return the product to Buyer.
Safety Warnings The exclamation point within a triangle is intended to warn the operator or service personnel of operation and maintenance factors relating to the product and its operating environment which could pose a safety hazard. Always observe standard safety precautions during installation, operation and maintenance of this product. Only qualified and authorized service personnel should carry out adjustment, maintenance or repairs to this instrument.
Regulatory Information FCC-15 User Information This equipment has been tested and found to comply with the limits of the Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Declaration of Conformity Manufacturer’s Name: RAD Data Communications Ltd. Manufacturer’s Address: 12 Hanechoshet St. Tel Aviv 69710 Israel declares that the product: Product Name: AMC-101 Conforms to the following standard(s) or other normative document(s): EMC: Safety: EN 55022 (1994) Limits and methods of measurement of radio disturbance characteristics of information technology equipment.
Contents CHAPTER 1 – INTRODUCTION 1.1 General ............................................................................................................................................. 1-1 Retimed Modules ................................................................................................................................. 1-1 Transparent Modules ............................................................................................................................ 1-1 1.2 Features ........
Contents SM/ST/13LH/R Module ....................................................................................................................... 2-15 SM/FC/13LH/R Module....................................................................................................................... 2-16 SM/ST/15L/R Module.......................................................................................................................... 2-17 SM/ST/15LH/R Module ...............................................
Contents List of Figures Figure 1-1 Dissimilar Device Connectivity .................................................................................................. 1-3 Figure 1-2 Dual Similar Device Connectivity............................................................................................... 1-3 Figure 1-3 WRAP: Dual Single Mode (SM) to Multimode (MM) Conversion ............................................... 1-4 Figure 1-4 Single Interface SM to MM (Wrap) ..................................
List of Tables Figure 2-36 10BT/B Module Front Panel................................................................................................... 2-35 Figure 3-1 AMC-101 Front Panel................................................................................................................ 3-1 Figure 3-2 Jumper Locations and Functions ................................................................................................ 3-2 Figure 3-3 Connector Pin Assignment ............................
Chapter 1 Introduction 1.1 General The AMC-101, a Universal Converter and Repeater, provides retimed or transparent conversion of optical and electrical signals for ATM, FDDI, Fast Ethernet and other protocols at data rates up to 155 Mbps. The modularity of the AMC-101 interfaces enables field-changeable conversion between any two media. Transparent modules provide cost-effective media conversion without reclocking.
AMC-101 Installation & Operation Manual Chapter 1 - Introduction 1.2 Features Modular Media Converter and Repeater, Media types supported: • Single Mode Fiber • Multimode Fiber • STP • UTP • Coax Retimed media conversion for 51 Mbps, 100 Mbps and 155 Mbps. Transparent media conversion up to 155 Mbps.
AMC-101 Installation & Operation Manual Chapter 1 - Introduction 1.3 General Applications A single AMC-101 is used to connect two devices operating with different fiber or electrical interfaces (see Figure 1-1). UTP Cat 5 1300 nm 155 Mbps ATM Station Single Mode Fiber AMC-101 ATM Switch Figure 1-1 Dissimilar Device Connectivity A pair of AMC-101s connect two similar devices over different media types (see Figure 1-2).
AMC-101 Installation & Operation Manual Chapter 1 - Introduction A single AMC-101 in WRAP mode can be used for double conversion between single mode and multimode fiber for a dual attached FDDI station or concentrator (see Figure 1-3). Figure 1-3 WRAP: Dual Single Mode (SM) to Multimode (MM) Conversion A single AMC-101 equipped with a single interface in WRAP mode can be used for conversion between single mode and multimode fiber (see Figure 1-4).
AMC-101 Installation & Operation Manual Chapter 1 - Introduction The FDDI applies scrambling to data when operating over UTP, but not doing so when operating over fiber. Because of this, AMC-101 can only work in pairs for extending FDDI connections over fiber (see Figure 1-5).
AMC-101 Installation & Operation Manual Chapter 1 - Introduction 1.4 Fast Ethernet Applications • Point to Point Link using a pair of Fiber Optic Cables running in HD (Half Duplex) 100-BaseFX: Problem: In a point to point application, in HD, the maximum range is limited to 412m. Fiber Optic Link Up to 412m Server Printer Fiber Optic Link Up to 412m Laptop PC Figure 1-6 Half Duplex Point-to-Point Connection Solution: Using two AMC-M/100BT/B modules can extend the range up to tens of kilometers.
AMC-101 Installation & Operation Manual • Chapter 1 - Introduction Repeater based LAN Link using standard UTP at HD (Half Duplex). Problem: Range is limited to 100m from the repeater. UTP Up to 100m Fast Ethernet Station (Laptop) Repeater UTP Up to 100m Fast Ethernet Station Figure 1-8 Repeater Half Duplex Connection over UTP Solution: Using two AMC-101s with AMC-M/100BT/B modules can extend the range up to tens of kilometers.
AMC-101 Installation & Operation Manual Chapter 1 - Introduction • Extension of a point to point FD (Full Duplex) Fast Ethernet connection: Problem: The distance between two FD stations running on UTP needs to be extended. UTP Up to 100m FD Fast Ethernet Station FD Fast Ethernet Station Figure 1-10 Point-to-Point Full Duplex Connection Solution: Using two AMC-101s with AMC-M/100BT/R modules can extend the range up to tens of kilometers.
AMC-101 Installation & Operation Manual • Chapter 1 - Introduction Extension of a Switched Based Fast Ethernet LAN (FD - Full Duplex) Problem: The range of a FD Fast Ethernet LAN running on UTP has to be extended. UTP Up to 100m IBM Printer UTP Up to 100m Fast Ethernet Laptop Station FD Fast Ethernet Switch UTP Up to 100m Fast Ethernet Station Figure 1-12 Full Duplex Connection over UTP Solution: Using AMC-101s with AMC-M/100BT/R modules can extend the range up to tens of kilometers.
AMC-101 Installation & Operation Manual Chapter 1 - Introduction 1.
AMC-101 Installation & Operation Manual Chapter 1 - Introduction Table 1-1 Optical Module Characteristics Module Name MM/ST/85* MM/SC/13** MM/ST/13** SF1/FC*** SF2/FC*** SF1/ST*** SF2/ST*** SM/FC/13** SM/FC/13L** (LASER) Protocols Supported Fiber Type Connector Typical Dynamic (Wavelength) Type Distance Range Optical Sensitivity Power (Typical) Token Ring, Ethernet only 62.5/125 (850 nm) ST 18 dB -18 dBm -30 dBm TAXI, FDDI, Fast Ethernet, STS-1, STS3c/STM-1 62.
AMC-101 Installation & Operation Manual Chapter 1 - Introduction Table 1-1 Optical Module Characteristics (Cont.
AMC-101 Installation & Operation Manual Chapter 1 - Introduction Table 1-2 Electrical Module Characteristics Module Name Protocols Supported Cable Type Connector Type Range Impedance (Ohms) UTP/155* STS-3c UTP Cat 5 Shielded RJ-45 100 m 100 STP/155* STS-3c STP Type 1 DB-9 100 m 150 UTP/100* FDDI, UTP Cat 5 Shielded RJ-45 100 m 100 CX/BNC/155** STS-3c STM-1 Coax BNC 12.7 dB* 75 CX/DIN/155** STS-3c STM-1 Coax DIN 47295 1.6/5.6 Coaxial connector 12.
Chapter 1 - Introduction 1-14 Specifications AMC-101 Installation & Operation Manual
Chapter 2 Installation & Setup 2.1 Unpacking Before Unpacking Inspect the equipment container before unpacking. Note and report evidence of damage immediately. Unpacking Procedure • Place the container on a clean flat surface. Cut all straps and open or remove top. • Remove the unit carefully and place it securely on a clean surface. • Remove all packing material. • Inspect the unit for damage. Report any damage immediately. 2.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual Figure 2-1 AMC-101 Rear Panel AC Version Figure 2-2 AMC-101 Rear Panel DC Version Installation of a Single Unit Rack adapter components for installing a single unit include one short bracket and one long bracket.
AMC-101 Installation & Operation Manual Installation of Two Units Chapter 2 - Installation & Setup Rack adapter components for installing two units include two long side rails (one for each unit) which slide one into the other fastening the two units together, and two short side brackets which hold the two units in the 19'' rack (see Figure 2-4). Figure 2-4 Installation of Two Units (a) To install two units follow these instructions: 1.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup Figure 2-5 Installation of Two Units (b) 2.3 Cable Connections AC Power Connection Warning AC power should be supplied to AMC-101 through a 1.5m (5 ft) standard power cord terminated by a grounded 3-wire plug. When applying AC power, first connect the plug of the AC cable to the power connector on the rear panel of AMC-101 and then to the mains outlet.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup 2.4 AMC-101 Modules The upper part of the module front panel is AMC-R for a Retimed Timing mode; the lower part is AMC-T for a Transparent Timing mode. In both panels, the module name is labeled at panel’s bottom.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup MM/SC/13/T Module Figure 2-7 MM/SC/13/T Module Front Panel 2-6 AMC-101 Modules Wavelength: 1300 nm Connector: SC Used with: Multimode fiber Protocols supported: Any two level optical protocols up to 155 Mbps Timing mode: Transparent Coding method: 4B/5B, NRZ Optical output into 62.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup MM/ST/13/R Module Figure 2-8 MM/ST/13/R Module Front Panel Wavelength: 1300 nm Connector: ST Used with: Multimode fiber Protocols supported: STS-3c, STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Coding method: 4B/5B, NRZ Optical output into 62.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup MM/ST/13/T Module Figure 2-9 MM/ST/13/T Module Front Panel 2-8 AMC-101 Modules Wavelength: 1300 nm Connector: ST Used with: Multimode fiber Protocols supported: Any two level optical protocols up to 155 Mbps Timing mode: Transparent Coding method: 4B/5B, NRZ Optical output into 62.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup SM/ST/13/R Module Figure 2-10 SM/ST/13/R Module Front Panel Wavelength: 1300 nm Connector: ST Used with: Single mode fiber Protocols supported: STS-3c, STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Coding method: 4B/5B, NRZ Optical output into 9/125 fiber: -15 dBm Receiver sensitivity: -31 dBm Maximum input power: -1 dBm AMC-101 Modules 2-9
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup SM/ST/13/T Module Figure 2-11 SM/ST/13/T Module Front Panel 2-10 Wavelength: 1300 nm Connector: ST Used with: Single mode fiber Protocols supported: Any two level optical protocols up to 155 Mbps Timing mode: Transparent Coding method: 4B/5B, NRZ Optical output into 9/125 fiber: -15 dBm Receiver sensitivity: -31 dBm Maximum input power: -1 dBm AMC-101 Modules
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup SM/FC/13/T Module Figure 2-12 SM/FC/13/T Module Front Panel Wavelength: 1300 nm Connector: FC Used with: Single mode fiber Protocols supported: Any two level optical protocols up to 155 Mbps Timing mode: Transparent Coding method: 4B/5B, NRZ Optical output into 9/125 fiber: -15 dBm Receiver sensitivity: -31 dBm Maximum input power: -1 dBm AMC-101 Modules 2-11
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup SM/ST/13L/R Module Figure 2-13 SM/ST/13L/R Module Front Panel 2-12 Wavelength: 1300 nm Connector: ST Used with: Single mode fiber Protocols supported: STS-3c, STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Coding method: 4B/5B, NRZ Optical output into 9/125 fiber: -12 dBm Receiver sensitivity: -31 dBm Maximum input power: -1 dBm AMC-101 Modules
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup SM/ST/13L/T Module Figure 2-14 SM/ST/13L/T Module Front Panel Wavelength: 1300 nm Connector: ST Used with: Single mode fiber Protocols supported: Any two level optical protocols up to 155 Mbps Timing mode: Transparent Coding method: 4B/5B, NRZ Optical output into 9/125 fiber: -12 dBm Receiver sensitivity: -31 dBm Maximum input power: -1 dBm AMC-101 Modules 2-13
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup SM/SC/13L/R Module Figure 2-15 SM/SC/13L/R Module Front Panel 2-14 Wavelength: 1300 nm Connector: SC Used with: Single mode fiber Protocols supported: STS-3c; STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Coding method: 4B/5B, NRZ Optical output into 9/125 fiber: -12 dBm Receiver sensitivity: -31 dBm Maximum input power: -1 dBm AMC-101 Modules
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup SM/ST/13LH/R Module Figure 2-16 SM/ST/13LH/R Module Front Panel Wavelength: 1300 nm Connector: ST Used with: Single mode fiber Protocols supported: STS-3c; STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Coding method: 4B/5B, NRZ Optical output into 9/125 fiber: -2 dBm Receiver sensitivity: -34 dBm Maximum input power: -1 dBm AMC-101 Modules 2-15
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual SM/FC/13LH/R Module Figure 2-17 SM/FC/13LH/R Module Front Panel 2-16 Wavelength: 1300 nm Connector: FC Used with: Single mode fiber Protocols supported: STS-3c; STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Coding method: 4B/5B, NRZ Optical output into 9/125 fiber: -2 dBm Receiver sensitivity: -34 dBm Maximum input power: -1 dBm AMC-101 Modules
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup SM/ST/15L/R Module Figure 2-18 SM/ST/15L/R Module Front Panel Wavelength: 1550 nm Connector: ST Used with: Single mode fiber Protocols supported: STS-3c, STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Coding method: 4B/5B, NRZ Optical output into 9/125 fiber: -12 dBm Receiver sensitivity: -31 dBm Maximum input power: -1 dBm AMC-101 Modules 2-17
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual SM/ST/15LH/R Module Figure 2-19 SM/ST/15LH/R Module Front Panel 2-18 Wavelength: 1550 nm Connector: ST Used with: Single mode fiber Protocols supported: STS-3c; STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Coding method: 4B/5B, NRZ Optical output into 9/125 fiber: -2 dBm Receiver sensitivity: -34 dBm Maximum input power: -1 dBm AMC-101 Modules
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup SM/FC/15LH/R Module Figure 2-20 SM/FC/15LH/R Module Front Panel Wavelength: 1550 nm Connector: FC Used with: Single mode fiber Protocols supported: STS-3c, STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Coding method: 4B/5B, NRZ Optical output into 9/125 fiber: -2 dBm Receiver sensitivity: -34 dBm Maximum input power: -1 dBm AMC-101 Modules 2-19
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup MM/ST/85/T Module Figure 2-21 MM/ST/85/T Module Front Panel 2-20 Wavelength: 850 nm Connector: ST Used with: Multimode fiber Protocols supported: Token Ring, Ethernet only Timing mode: Transparent Coding method: 4B/5B, NRZ, Manchester Optical output into 62.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup SF1/ST/R Module Figure 2-22 SF1/ST/R Module Front Panel Wavelength: Transmit: 1300 nm; Receive: 1550 nm Connector: ST Used with: Single mode fiber Protocols supported: STS-3c, STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Optical output into 9/125 fiber: -12 dBm Receiver sensitivity: -29 dBm AMC-101 Modules 2-21
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup SF2/ST/R Module Figure 2-23 SF2/ST/R Module Front Panel 2-22 Wavelength: Transmit: 1550 nm; Receice: 1300 nm Connector: ST Used with: Single mode fiber Protocols supported: STS-3c, STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Optical output into 9/125 fiber: -12 dBm Receiver sensitivity: -29 dBm AMC-101 Modules
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup SF1/FC/R Module Figure 2-24 SF1/FC/R Module Front Panel Wavelength: Transmit: 1300 nm; Receive: 1550 nm Connector: FC Used with: Single mode fiber Protocols supported: STS-3c, STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Optical output into 9/125 fiber: -12 dBm Receiver sensitivity: -29 dBm AMC-101 Modules 2-23
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup SF2/FC/R Module Figure 2-25 SF2/FC/R Module Front Panel 2-24 Wavelength: Transmit: 1550 nm; Receive: 1300 nm Connector: FC Used with: Single mode fiber Protocols supported: STS-3c, STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Optical output into 9/125 fiber: -12 dBm Receiver sensitivity: -29 dBm AMC-101 Modules
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup CX/BNC/155/R Module Figure 2-26 CX/BNC/155/R Module Front Panel Connector: BNC Used with: Coax cable Protocols supported: STS-3c, STM-1 Timing mode: Retimed Range calculation: 12.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup CX/DIN/155/R Module Figure 2-27 CX/DIN/155/R Module Front Panel 2-26 Connector: 1.6/5.6 Coax Used with: Coax cable Protocols supported: STS-3c, STM-1 Timing mode: Retimed Range calculation: 12.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup STP/155/R Module Figure 2-28 STP/155/R Module Front Panel Connector: DB-9 Used with: STP type 1 cable Protocols supported: STS-3c Timing mode: Retimed Coding method: NRZ Range: 100 m Impedance: 150 Ω Table 2-1 STP/155/R Pinout Pinout Pin 1 Rx+ Pin 2 Pin 3 Pin 4 Pin 5 Tx+ Pin 6 Rx- Pin 7 Pin 8 Pin 9 Tx- AMC-101 Modules 2-27
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup STP/155/T Module Figure 2-29 STP/155/T Module Front Panel Connector: DB-9 Used with: STP type 1 cable Protocols supported: STS-3c Timing mode: Transparent Coding method: NRZ Range: 50 m Impedance: 150 Ω Table 2-2 STP/155/T Pinout Pinout Pin 1 Rx+ Pin 2 Pin 3 Pin 4 Pin 5 Tx+ Pin 6 Rx- Pin 7 Pin 8 Pin 9 2-28 AMC-101 Modules Tx-
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup UTP/155/R Module Figure 2-30 UTP/155/R Module Front Panel Connector: Shielded RJ-45 Used with: UTP Cat 5 Protocols supported: STS-3c Timing mode: Retimed Coding method: NRZ Range: 100 m Impedance: 100 Ω Table 2-3 UTP/155/R Pinout Pinout Pin 1 Tx+ Pin 2 Tx- Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Rx+ Pin 8 Rx- AMC-101 Modules 2-29
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup UTP/155/T Module Figure 2-31 UTP/155/T Module Front Panel Connector: Shielded RJ-45 Used with: UTP Cat 5 Protocols supported: STS-3c Timing mode: Transparent Coding method: NRZ Range: 50 m Impedance: 100 Ω Table 2-4 UTP/155/T Pinout Pinout Pin 1 Tx+ Pin 2 Tx- Pin 3 Pin 4 Pin 5 Pin 6 2-30 AMC-101 Modules Pin 7 Rx+ Pin 8 Rx-
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup UTP/100/R Module Figure 2-32 UTP/100/R Module Front Panel Connector: Shielded RJ-45 Used with: UTP Cat 5 Protocols supported: FDDI Timing mode: Retimed Coding method: NRZ Range: 100 m Impedance: 100 Ω Table 2-5 UTP/100/R Pinout Pinout Pin 1 Tx+ Pin 2 Tx- Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Rx+ Pin 8 Rx- AMC-101 Modules 2-31
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup UTP/100/T Module Figure 2-33 UTP/100/T Module Front Panel Connector: Shielded RJ-45 Used with: UTP Cat 5 Protocols supported: FDDI Timing mode: Transparent Coding method: NRZ Range: 50 m Impedance: 100 Ω Table 2-6 UTP/100/T Pinout Pinout Pin 1 Tx+ Pin 2 Tx- Pin 3 Pin 4 Pin 5 Pin 6 2-32 AMC-101 Modules Pin 7 Rx+ Pin 8 Rx-
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup 100BT/B Module AMC-B TX LINK RX COLL 100BTX Figure 2-34 100BT/B Module Front Panel Connector: Shielded RJ-45 Used with: UTP Cat 5 Protocols supported: Fast Ethernet (100 Base TX): Half Duplex on UTP side and Full Duplex on second module side Timing mode: Retimed & Bridged Coding method: 4B/5B, MLT-3 Range: 80 m Impedance: 100 Ω Special Features Bridging, Filtering, Half Duplex to Full Duplex conversion Table 2-7 10
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup 100BT/R Module AMC-R TX LINK RX 100BTX Figure 2-35 100BT/R Module Front Panel Connector: Shielded RJ-45 Used with: UTP Cat 5 Protocols supported: Fast Ethernet (100 Base TX): Half or Full Duplex (HDX to HDX or FDX to FDX) Timing mode: Retimed Coding method: 4B/5B, MLT-3 Range: 80 m Impedance: 100 Ω Table 2-8 100BT/R Module Pinout Pinout Pin 1 Tx+ Pin 2 Tx- Pin 3 Rx+ Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 2-34 AMC-10
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup 10BT/B Module AMC-B TX LINK RX COLL 10BT Figure 2-36 10BT/B Module Front Panel Connector: Shielded RJ-45 Used with: UTP Cat 5 Protocols supported: Ethernet (10Base-T): Half or Full Duplex Timing mode: Retimed Range: 100 m Impedance: 100 Ω Table 2-9 10BT/B Module Pinout Pinout Pin 1 Tx+ Pin 2 Tx- Pin 3 Rx+ Pin 4 Pin 5 Pin 6 Rx- Pin 7 Pin 8 Note 10BT/B modules (Half Duplex or Full Duplex) operate with Transpa
Chapter 3 Operation 3.1 Controls and Indicators All controls and indicators are located on the front panel of AMC-101.
AMC-101 Installation & Operation Manual Chapter 3 - Operation DB-9 Connector (ALARM) JP2 AC AMC-RELAY (ALARM) Card Power Supply JP1 GND JP2 JP1 JP4 VCC JP6 ERR-CFG JP7 IDLE-EN AMC-101 Module AMC-101 Module LEDs Card Figure 3-2 Jumper Locations and Functions Table 3-3 Jumper ID 3-2 Function JP2 ERR-CFG JP7 Idle-Enable Controls and Indicators Functions and Settings Conditional Setting Mounted (Factory Default) If mounted, idle will be transmitted when no signal is received from the oth
AMC-101 Installation & Operation Manual Chapter 3 - Operation 3.2 Cable Connections Grounding Note DC adapter Connection. In order to protect the AMC-1 from electrostatic discharge (ESD), use a DC adapter where the (-) DC pole is connected to the protective earth. 3.3 Dry Contact Circuit and Connector for Alarms A dry circuit with a 9-pin D-type connector on the rear panel, has been added to the unit to signal minor and major alarms.
AMC-101 Installation & Operation Manual Chapter 3 - Operation Example: For the RED ALARM the common input (COM) pin is 9. If there is no power failure, it connects to pin 4 (OK). If there is a failure, pin 9 connects to pin 5 (FAIL). 3.4 Turning on the AMC-101 Connect the AC cable of AMC-101 to the mains outlet. The POWER indicator on the front panel should light up.
AMC-101 Installation & Operation Manual Chapter 3 - Operation PWR LED Dry Contact FLT LED Relay 1 WRAP LED Control Logic WRAP Button RATE Switch Relay 2 Relay 3 51 100 155 Other Mux Control Mux Idle AMC-101 Module Fiber/Copper Transmitter Fiber/Copper Receiver Mux Control REF Retiming Status SIG LED Mux AMC-101 Module Module Connector Idle Fiber/Copper Transmitter REF Fiber/Copper Receiver Retiming Status SIG LED Frequency Sources Reference Frequency MUX Figure 3-4 AMC-101 Block Dia
AMC-101 Installation & Operation Manual Chapter 3 - Operation 3.5 Normal Operation Once powered on, the POWER indicator should light up and the FLT should be turned off. If the FLT indicator blinks, a configuration error exists: the combination of the card types and the selected data rate is illegal. Each AMC-101 module contains a SIG indicator. If the SIG indicator is turned off; no signal is received by the module.