Owner`s manual

Installation
2-4
6) Tighten all four screws with a screwdriver to secure the frame firmly against the wall.
7) Replace the removed modules in their slots.
Installing the ACE3600 in a 19" Rack
The following screw mount installation procedure should be used to install the ACE3600 8 I/O
(19”) frame in a 19" rack.
Note: The brackets for 19" rack installation are not provided with the RTU and should be
ordered separately.
Procedure 2-2 How to Mount the RTU in a 19" Rack Unit
1) Press the small metal bracket into the slot of the larger bracket. See Figure 2-4.
2) Secure the two brackets together with two M5 screws (supplied), according to the desired
depth of the unit on the rack. See Figure 2-4.
3) Repeat steps 1-2 for the other pair of brackets.
4) Using the supplied two screws, attach the combined brackets to the metal pole of a 19"
rack unit. See Figure 2-4. Repeat on other side.
Bracket Groove
Small Bracket
Large Bracket
Metal Pole
Figure 2-4. Installation of Brackets for 19" Rack Units
5) Hang the 19'' metal chassis on the brackets, so that the two teeth on the back of the metal
chassis hook onto the groove of the larger bracket.