User`s manual
5620 Model Descriptor for LA-110 User’s Manual Chapter 4 Port Configuration and Monitoring
SHDSL Port Monitoring 4-65
Table 4-34. SHDSL Port – Physical Layer – Current Day Data Statistics Parameters
Parameter Remarks
Port The selected port
SHDSL
Read-only
Type The interface type
SHDSL
Read-only
Time Elapsed The data of this group is for the current 24 hours period (one day). The Time Elapsed
field shows how much time passed since the beginning of the current interval (day).
Read-only
Errored Seconds The number of Errored Seconds.
Read-only
Severely Errored
Seconds (SESs)
The number of Severely Errored Seconds.
Read-only
CRC Anomalies The number of CRC anomalies.
Read-only
Loss of Sync
Word Seconds
(LOSWs)
The number of Loss of Sync Word Seconds
Read-only
Unavailable
Seconds (UASs)
The number of Unavailable Seconds.
Read-only
Intervals Data Statistics
To view intervals data statistics of the SHDSL port:
• In the LA-110 Node Draw, select the SHDSL port, right-click and select
Monitor > Physical Layer > Intervals Data.
A Monitor form appears, displaying the intervals data statistics results as
shown in Figure 4-44 and as listed in Table 4-35.