Specifications
Start, Programs, Racom, TrLoader, Firmware Transparent loader
1. Select Application/Upgrade firmware-Step1
(download the first part of firmware, takes approx. 45 sec, STATUS LED is flashing yellow slowly,
address 192.168.1.1)
2. Select Application/Upgrade bootloader
(download the new bootloader module, approx. 40 sec, STATUS LED is flashing yellow slowly,
address 192.168.1.1)
This step can be omitted, if the bootloader in RE is not older then version mentioned in the file:
c:\Racom\Trloader\fw_pkg\tr1-2.1.7.0\bootloader\COMPAT
The check is accomplished automatically at Upgrade firmware-Step2. If the return to the
step Upgrade bootloader is necessary then the report appears:
3. Select Application/Upgrade firmware-Step2
(download the second part of firmware, takes approx. 150 sec, STATUS LED is flashing green
slowly, address 192.168.1.2)
4. Select Application/Get device info
returns the actual fw version from the radio modem. It is also possible to set the customer's IP
address (Settings/Parameters/altIP) instead of the original 192.168.1.2 for reading the fw
version from other radio modem. The loader uses the addresses in order 192.168.1.1, 192.168.1.2
and altIP.
Narrowband radio modem ECONOMY RE400 – © RACOM s.r.o.18
Description