Intelligent Remote Power Management User Manual MTS switched PDU MT monitored PDU IPS-01, IP KVM GUI Software
Legal Information First English printing, October 2002 Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness of the contents. The information in this document is subject to change without notice. We are not liable for any injury or loss that results from the use of this equipment. Safety Instructions Please read all of these instructions carefully before you use the device. Save this manual for future reference.
Unpacking The equipment comes with the standard parts shown on the package contents. Check and make sure they are included and in good condition. If anything is missing, or damage, contact the supplier immediately.
< 1.1 > PDU meter setting & cascade LINK 1 OUT PDU cascade port ON CURRENT (A) 2 225 Current display ON 3 Dip switch 4 Reset button 1 OFF ON DIP DIP 2 3 4 5 6 7 8 1 2 3 4 5 6 RESET ■ For rackmount PDU, 2 3 4 on the front panel left , 1 on the rear panel Cascaded PDUs setting Using the dip switch no.
1st level PDU LINK 2nd level PDU CAT. 5 / 6 cable OUT LINK Up to 20 meters CURRENT (A) IP KVM 1 2 3 4 5 6 7 LINK Up to 20 meters ON 8 1 RESET 2 3 4 5 6 225 DIP ON 8 1 7 RESET DIP ON OUT CURRENT (A) 225 DIP ON CAT.
CyberView Matrix IP KVM 32 31 30 29 28 27 26 25 16 15 14 13 12 11 10 9 24 23 22 21 20 19 18 17 8 7 6 5 4 3 2 1 Other band IP KVM can NOT connect InfraPower PDU Each RJ-45 Multi port connect max. 16 pcs of InfraPower PDU ( 16 pcs InfraPower PDU x 2 for dual Multi port ) To Multi port 1st level PDU To LINK port of the 1st PDU LINK OUT CURRENT (A) 2nd level PDU CAT. 5 / 6 cable Up to 20 meters 225 ON 1 2 3 4 5 6 7 LINK CURRENT (A) CAT.
< 2.2 > IPS-01, free PDU management software, specially designed for IP KVM CyberView IP KVM allows the user to manage servers & PDUs together. Web-Based GUI (IPS-01) is applicable to the CyberView Connection only. No software application required to be installed on the PC. Skip the above step if the IP KVM has been already login Step 1. Open Internet Explorer ( I.E. ), version 6.0 or above Step 2. Enter the IP KVM address into the address bar - For Single IP KVM model, such as UIP-1602 - http://192.168.1.
< Overview > Aggregate current on the PDU Status of all connected PDUs Latest loading on each circuit of PDU Alarm threshold setup - Data refresh every 10 seconds - Disable Refresh during data input : save the changes < Control > On / Off status of each outlet Remote on / off outlet ( MTS switched PDU only ) Rename outlet device & PDU location - Data refresh every 10 seconds - Disable Refresh during data input : show the specified PDU status ( Select the PDU Level > View ) : save the changes : refresh