Specifications
Pure SinewaveWaveform (Battery Mode)
9 Hours Recover to 90% Capacity
BATTERY
Battery Type
Numbers of Battery
Typical Recharge Time
Charging Current (Max.)
Charging Voltage
Standard Model
Battery Type
Numbers of Battery
Long-Run Model
6
240.0VDC
Depending on
Applications
90%90%
88%
97%
EFFICIENCY
AC Mode
Battery Mode
ECO Mode
INPUT
MASTER serieS (1p/1p) - Tower
Derate to 60% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 208VAC.
If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.
L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
Symbols: / meant for OR; × meant for Multiply of.
All specifications, designs and contents are subjected to changes without prior notice.
• True Double-Conversion Online UPS
• Wide input voltage range (110~300VAC)
• Input Power Factor correction 0.99
• Output Power Factor 0.80
• Generator compatible
• LCD User Interface
• RS-232 communication port or mini slot for USB / RS-232 / AS400 /
SNMP communication
• Smart battery charger design for optimized battery performance
• Optional isolation transformer available
MODELS
Full specifications
Capacity
Volt-Amp
Watt
Low Line Transfer
Low Line Comeback
12V7AH
3
3
PRO801S/L/SI/LI
1000 VA
800 W
PRO802S/L/SI/LI
2000 VA
1600 W
12V7AH
6
12V9AH12V9AH
PRO803S/L/SI/LI
3000 VA
2400 W
PRO806S/L/SI/LI
6000 VA
4800 W
Single Phase In / Single Phase Out
Optional
176VAC ±3% @ 100% Load
110VAC ±3% @ 50% Load
176VAC ±3% @ 100% Load
110VAC ±3% @ 50% Load
186VAC @ 100% Load
120VAC @ 50% Load
186VAC @ 100% Load
120VAC @ 50% Load
PRO806C/CL/CI/CLI
6000 VA
4800 W
Depending on
Applications
12V7AH
7 Hours Recover to 90% Capacity
1A
Depending on Applications
20
273.0VDC ±1%
16
218.4VDC ±1%
89%
≦ 3% THD
≦ 6% THD
12V9AH
20
Depending on Applications
1A
273.0VDC ±1%
18~20 18~20
89%
176VAC ±3% @ 100% Load
110VAC ±3% @ 50% Load
PRO810S/L/SI/LI
10000 VA
8000 W
PRO810C/CL/CI/CLI
10000 VA
8000 W
OnlinE UPS
5
Online
Phase
Voltage Range
Isolation Transformer
OUTPUT
High Line Transfer
High Line Comeback
Synchronized Range
Battery Mode
Linear Load
Non-linear Load
Frequency Range
Power Factor
Output Voltage
AC Voltage Regulation (Battery Mode)
Frequency Range
Harmonic Distortion
Current Crest Ratio
Transfer Time
82.1VDC ±1%
88%
≦ 4% THD
≦ 7% THD
41.0VDC ±1%
85%
≦ 3% THD
≦ 6% THD
AC Mode to Battery Mode
300VAC ±3%
290VAC ±3%
46~54Hz or 56~64Hz
≧ 0.99 @ 100% Load
±1%
3:1
208/220/230/240VAC
46~54Hz or 56~64Hz
50Hz ±0.1Hz or 60Hz ±0.1Hz
Line Mode: Zero
Line Mode: ZeroInverter to Bypass
Line Mode: Zero
Line Mode: 4ms (Typical)
1A
4 Hours Recover to 90% Capacity
Depending on Applications
83%
160VAC ±5% or 80VAC ±5% @ 100% Load
110VAC ±5% or 50VAC ±5% @ 50% Load
175VAC ±5% or 85VAC ±5% @ 50% Load
300VAC ±5% or 150VAC ±5%
290VAC ±5% or 145VAC ±5%
±3%
3:1
40Hz or 70Hz
≧ 0.99 @ Nominal Voltage (100% Load)
208/220/230/240VAC or 110/115/120/127VAC
47~53Hz or 57~63Hz
50Hz ±0.25Hz or 60Hz ±0.3Hz
0.8Power Factor
ENVIRONMENT
Humidity
Noise Level
PHYSICAL
Dimension (mm) D×W×H
Net Weight (kgs)
Dimension (mm) D×W×H
Net Weight (kgs)
Standard Model
Long-Run Model
INDICATORS
LCD Display
ALARM
Battery Mode
Low Battery
Overload
Fault
Charging Current (Max.)
Charging Voltage
592×250×576
592×250×576
360×192×688
72
21
360×192×318
Less than 55dB @ 1 Meter
440×192×688
82
23
440×192×318
UPS Status, Load Level, Battery Level, Input/Output Voltage, Discharge Timer, Fault Conditions
Sounding every 4 seconds
Sounding every second
Sounding twice every second
Continuously sounding
20~90% RH @ 0~40°C (Non-condensing)
Regulations EN 62040-1-1:2003, EN 62040-2:2006, EN 61000-2-2:2002, EN 61000-4
13
7
14
7
26
13
28
13
81
25
Less than 58dB @ 1 Meter
273.0VDC ±1%
4A
592×250×576
83
27
592×250×576
82.1VDC ±1%
421×190×318
421×190×318
41.0VDC ±1%
397×145×220
397×145×220
8A
Less than 45dB @ 1 Meter
MANAGEMENT
Smart RS-232 / USB
Support Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix and MAC
PRO8015S/L/SI/LI
1500 VA
1200 W