Specifications

• True double-conversion
• DSP technology guarantees high performance
• Output Power Factor 0.8
• Wide input voltage range
• Active power factor correction in all phases
• 50Hz/60Hz frequency converter mode
• Eco mode operation for energy saving (ECO)
• Emergency power off function (EPO)
• Generator compatible
• Charger capacity expansion to 8A for long-run models
• SNMP+USB+RS-232 multiple communications
• 3-stage extendable charging design for optimized battery performance
• Adjustable battery numbers
• Optional N+X parallel redundancy
Master Series (3P/1P) - Rackmount
Full specifications
10000 VA
8000 W
PRO83110 (RS/RL)MODELS
20000 VA
16000 W
PRO83120 (RS/RL)
Phase
Volt-Amp
Watt
Capacity
3 Phase In / 1 Phase Out
Indications of Models: L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
All specifications, designs and contents are subjected to changes without prior notice.
OnlinE UPS
14
Online
INPUT
Power Factor
THDi
Frequency Range
Voltage Range
Low Line Transfer
176VAC (Phase Voltage) ±3% @ 100% Load
110VAC (Phase Voltage) ±3% @ 50% Load
Low Line Comeback
186VAC (Phase Voltage) ±3% @ 100% Load
120VAC (Phase Voltage) ±3% @ 50% Load
High Line Transfer 300VAC (Phase Voltage) ±3%
High Line Comeback 290VAC (Phase Voltage) ±3%
0.99 @ 100% Load
< 6% @ 100% Load
46~54Hz or 56~64Hz
≦5% THD
Frequency Range
Harmonic Distortion
Transfer Time
AC Mode to Battery Mode
Synchronized Range
Battery Mode
Inverter to Bypass
Linear Load
Non-Linear Load
AC Voltage Regulation (Battery Mode)
Output AC Voltage
Current Crest Ratio
Waveform (Battery Mode)
Power Factor
≦2% THD
OUTPUT
50Hz ±0.1Hz or 60Hz ±0.1Hz
±1%
208/220/230/240VAC
46~54Hz or 56~64Hz
3:1
Zero
Zero
Pure Sinewave
0.8
MANAGEMENT
Smart RS232 / USB Support Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix and MAC
1A
20pcs × 2 strings (18-20pcs adjustable)20pcs (18-20pcs adjustable)
89%
Overload
Fault
AC Mode
Battery Type
Numbers
Typical Recharge Time
Charging Current (max.)
Charging Voltage
Battery Type
Numbers
BATTERY
Standard Model
Long-Run Model
2A 4A
9 hours recover to 90%capacity
Charging Current (max.)
Charging Voltage
INDICATORS
LCD Panel
ALARM
Battery Mode
Low Battery
PHYSICAL
Standard Model
EFFICIENCY
Battery Mode 86% 87%
Dimension (mm) D×W×H
Net Weight (kgs)
13.65V ±1% per battery
13.65V ±1% per battery
12V9AH
UPS Status, Load Level, Battery Level, Input/Output Voltage, Discharge Timer, Fault Conditions
Depending on the capacity of external batteries.
Sounding every seconds
Sounding twice every seconds
Sounding every 4 seconds
Continuously sounding
Long-Run Model
Dimension (mm) D×W×H
Net Weight (kgs)
UPS Unit : 668 x 438 x 226 (6U)
2 x Battery Pack : 580 x 438 x 133 (3U)
UPS Unit : 38
Battery Pack : 2 x 63
668×438×226 (6U)
38
Humidity
Noise Level
ENVIRONMENT
0-95% Relative Humidity @ 0~40°C (Non-Condensing)
Less than 58dB @ 1 Meter Less than 60dB @ 1 Meter
Regulations EN 62040-2:2006, EN61000-2-2:2002, EN 61000-4
668×438×133
23
UPS Unit : 668 x 438 x 133 (3U)
Battery Pack : 580 x 438 x 133 (3U)
UPS Unit : 23
Battery Pack : 63