Specifications

MANAGEMENT
Smart RS232 / USB Support Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix and MAC
2A
20 x 2 strings (18-20pcs adjustable)
89%
≦5% THD
Frequency Range
Harmonic Distortion
Transfer Time
AC Mode to Battery Mode
Synchronized Range
Battery Mode
Inverter to Bypass
Linear Load
Non-Linear Load
AC Voltage Regulation (Battery Mode)
Output AC Voltage
Current Crest Ratio
Waveform (Battery Mode)
Power Factor
Overload
Fault
AC Mode
Battery Type
Numbers
Typical Recharge Time
Charging Current (max.)
Charging Voltage
Battery Type
Numbers
BATTERY
1A
Standard Model
Long-Run Model
8A4A
20 (18-20 adjustable)
9 hours recover to 90%capacity
Charging Current (max.)
Charging Volta
ge
INDICATORS
LCD Panel
ALARM
Battery Mode
Low Battery
PHYSICAL
EFFICIENCY
Battery Mode
≦5% THD
89%
86%
592×250×576
28
592×250×576
83
≦6% THD
85%
83%
592×250×826
91
592×250×826
144
87%
≦2% THD
88%
592×250×826
37
815×250×826
164
Standard Model
Long-Run Model
Dimension (mm) D×W×H
Net Weight (kgs)
Dimension (mm) D×W×H
Net Weight (kgs)
Humidity
Noise Level
ENVIRONMENT
0-95% Relative Humidity @ 0~40°C (Non-Condensing)
Less than 58dB @ 1 Meter
≦7% THD
NA
NA
87%
83%
815×250×826
144
Less than 60dB @ 1 Meter
Power Factor Correction
Frequency Range
OUTPUT
0.99 @ 100% Load
45~54Hz or 56~64Hz
50Hz ±0.1Hz or 60Hz ±0.1Hz
±1%
208/220/230/240VAC
46~54Hz or 56~64Hz
3:1
Zero
Zero
0.8
Pure Sinewave
13.65DC ±1% per Battery
13.65DC ±1% per Battery
12V9AH
UPS Status, Load Level, Battery Level, Input/Output Voltage, Discharge Timer, Fault Conditions
Depending on the capacity of external batteries.
Sounding every seconds
Sounding twice every seconds
Sounding every 4 seconds
Continuously sounding
• True Double-Conversion Online UPS
• DSP technology guarantees high performance
• Output Power Factor 0.80
• Input Power Factor Correction 0.99
• Wide input voltage range
• Active power factor correction in all phases
• Build-in phase auto aapt function simplifies wire installation
• 50/60Hz frequency converter mode
• Programmable power management outlets
• Emergency Power Off (EPO) function
• ECO Mode Operation for energy saving
• Charger capacity expansion to 8A for long-run models
• SNMP+USB+RS232 multiple communications
• 3-stage extendable charging design for optimized battery performance
• Adjustable battery numbers
• Maintenance bypass available
• Optional N+X parallel redundancy
• Optional isolation transformer available
Master Series (3P/1P) - TOWER
Full specifications
10000 VA
8000 W
15000 VA
12000 W
20000 VA
16000 W
INPUT
PRO83110SMODELS PRO83110 (L/LI) PRO83115 (S/L/LI) PRO83120S PRO83120 (L/LI)
Phase
Isolation Transformer
Volt-Amp
Watt
Voltage Range
Capacity
Optional
3 Phase In / 1 Phase Out
Low Line Transfer
176VAC (Phase Voltage) @ 100% Load
110VAC (Phase Voltage) @ 50% Load
Low Line Comeback
186VAC (Phase Voltage) @ 100% Load
120VAC (Phase Voltage) @ 50% Load
High Line Transfer
276VAC (Phase Voltage) @ 100% Load
300VAC (Phase Voltage) @ 50% Load
High Line Comeback
266VAC (Phase Voltage) @ 100% Load
290VAC (Phase Voltage) @ 50% Load
Protection IP20
Regulations EN 62040-2:2006, EN61000-2-2:2002, EN 61000-4
Indications of Models: L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
All specifications, designs and contents are subjected to changes without prior notice.