Specifications
Battery Type
Numbers
Typical Recharge Time
Charging Current (max.)
BATTERY
Charging Voltage
86%
83%
88%
85%
90%
88%
EFFICIENCY
AC Mode
Battery Mode
MASTER Series (1P/1P) - 2-in-1 Rack/Tower
• True Double-Conversion Online UPS
• Rack or Tower design
• Wide input voltage range (110~300VAC)
• Input Power Factor correction 0.99
• Output Power Factor 0.90
• 50/60Hz frequency converter mode
• Hot-Swappable battery design
• Programmable power management outlets
• Emergency Power Off (EPO) function
• ECO Mode Operation for energy saving
• General Compatible
• Charger capacity expansion to 8A for long-run models
• SNMP+USB+RS232 multiple communications
• Smart battery charger design for optimized battery performance
• Selectable output voltage via LCD panel
• Accessories: External maintenance bypass switch * SNMP card
Full specifications
#1: Based on load percentage 100%~80%/ 80%~70%/ 70%~60%/ 60%~0%.
Indications of Models: L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
All specifications, designs and contents are subjected to changes without prior notice.
INPUT
1000 VA
900 W
PRO801 (RS/RL)
800 W
1500 VA
1350 W
PRO8015 (RS/RL)
1200 W
2000 VA
1800 W
PRO802 (RS/RL)
1500 W
3000 VA
2700 W
PRO803 (RS/RL)
2400 W
6000 VA
5400 W
PRO806 (RS/RL)
5400 W
10000 VA
9000 W
PRO810 (RS/RL)
9000 W
MODELS
Capacity
Single Phase In / Single Phase Out (with ground)Phase
Voltage Range
Low Line Transfer
Volt-Amp
Watt
Standard Model
Long-Run Model
Low Line Comeback
High Line Transfer
High Line Comeback
Frequency Range
Power Factor Correction
Output Voltage
85/75/65/60VAC ±5% or 170/150/130/120VAC ±5%
80/70/60/55VAC ±5% or 160/140/120/110VAC ±5%
#1
150VAC ±5% or 300VAC ±5%
140VAC ±5% or 290VAC ±5%
≧ 0.99 @ nominal voltage (100%load)
40~70Hz
50Hz ±0.2Hz or 60Hz ±0.2Hz
≦2% THD
≦8% THD
±1%
110/115/120/127VAC or 208/220/230/240VAC
47~53Hz or 57~63Hz
5:1 (max.)
Zero
Zero
Pure Sinewave
186 VAC ±3% @ 100% Load or 120 VAC ±3% @ 50% Load
176 VAC ±3% @ 100% Load or 110 VAC ±3% @ 50% Load
300VAC ±3%
290VAC ±3%
≧0.99 @ 100% Load
46~54Hz or 56Hz~64Hz
50Hz ±0.1Hz or 60Hz ±0.1Hz
≦2% THD
≦6% THD
±1%
208/220/230/240VAC
46~54Hz or 56~64Hz
3:1
AC Mode to Battery Mode
Synchronized Range
Battery Mode
Inverter to Bypass
Linear Load
Non-Linear Load
AC Voltage Regulation (Battery Mode)
Frequency Range
Current Crest Ratio
Harmonic Distortion
Transfer Time
Waveform (Battery Mode)
OUTPUT
Tower Design
(Floor-Standing Tower)
Rack Design
Battery Type
Numbers
Standard Model
Long-Run Model
Charging Current (max.)
Charging Voltage
9 hours recover to 90% capacity
4 hours recover to 90% capacity
4A/8A
27.4VDC ±1%
41.1VDC ±1%
54.7VDC ±1%
82.1VDC ±1% 273VDC ±1%
1A 1A
4A
20
Depending on Applications
27.4VDC ±1%
41.1VDC ±1%
54.7VDC ±1%
82.1VDC ±1% 273VDC ±1%
12V9AH 12V7AH 12V9AH
2 3 4 6 20 20
2 3 4 6
UPS Status, Load Level, Battery Level, Input/Output Voltage, Discharge Timer, Fault Conditions
INDICATORS
LCD Panel
ALARM
Low Battery Sounding every seconds
Overload Sounding twice every seconds
Battery Mode Sounding every 4 seconds
Fault Continuously sounding
PHYSICAL
Standard Model
Dimension (mm) D×W×H
Net Weight (kgs)
12.9 20.617.6 28
380×438×88 [2U]
480×438×88 [2U]
480×438×88 [2U]
600×438×88 [2U]
UPS Unit : 580×438×133 [3U]
Battery Pack : 580×438×133 [3U]
UPS Unit : 17
Battery Pack : 57
8.6
380×438×88 [2U]
10.7
480×438×88 [2U]
Humidity
Noise Level
20-90% Relative Humidity @ 0~40°C (Non-Condensing)
Less than 50dB @ 1 Meter
Regulations EN 62040-1:2008, EN 62040-2:2006, EN 61000-4-2:2009
Smart RS232 / USB
MANAGEMENT
Support Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix and MAC
ENVIRONMENT
Long-Run Model
Dimension (mm) D×W×H
Net Weight (kgs)
11.3
480×438×88 [2U]
13.8
600×438×88 [2U]
17
580×438×133 [3U]
UPS Unit : 20
Battery Pack : 63
UPS Unit : 668×438×133 [3U]
Battery Pack : 580×438×133 [3U]
20
668×438×133 [3U]
OnlinE UPS
9
Online