Specifications

1260-14 User Manual
Module Specific Syntax 3-14 EADS North America Defense
Test and Services, Inc. © 1992
NOTE:
The BUSY line is only valid when synchronous operations
are defined and armed. Spurious signals at other times
should be ignored by the user.
Example:
This command sets the polarity of the BUSY signal to negative
within the module at address 2.
SETUP 2.BUSY,NEG
SETUP CLKIN
command
Syntax: SE[TUP] <address>.CL[KIN],POS | NEG
<address>::= Module address of the 1260-14 (1-12)
Description: This command defines the active edge of the CLKIN
handshake signal. Setting CLKIN to POS causes the module to
trigger on the positive (or rising) edge of the CLKIN signal. Setting
the polarity to NEG causes the module to trigger on the negative
(or falling) edge of the CLKIN signal. The default power-up
condition is POS.
NOTE:
The CLKIN line is only monitored when synchronous
operations are defined and armed. Spurious signals at other
times will be ignored.
Example:
This command sets the active edge of the CLKIN signal to
negative within the module at address 3.
SETUP 3.CLKIN, NEG