Specifications

1260-14 User Manual
Addendum Page 6/98 3
For example, if the <Option-01T Base Address> is 204000 (hex), the modules with the addresses 1
through 12 would have the base addresses as shown in the following table.
Module Address Base A24 Address for Module (Hex)
1 204401
2 204801
3 204C01
4 205001
5 205401
6 205801
7 205C01
8 206001
9 206401
10 206801
11 206C01
12 207001
If the base address of the Option-01T is 200000 (hex), then module address 1 would begin at A24
address 200401, module 2 would begin at 200801, and so on.
1260-14 Register Description
The 1260-14 register map is shown in the table below. The <Base Address> is computed as shown
in the preceding section.
Offset from <Base Address>
(Hex)
Description
0 Data Register for Channels 1 - 8
2 Data Register for Channels 9-16
4 Data Register for Channels 17-24
6 Data Register for Channels 25-32
8 Data Register for Channels 33-40
A Data Register for Channels 41-48
C Data Register for Channels 49-56
E Data Register for Channels 57-64
10 Data Register for Channels 64-72
12 Data Register for Channels 73-80
14 Data Register for Channels 81-88
16 Data Register for Channels 89-96
18 Enable Control Register #1
1A Enable Control Register #2