Technical data
1260-118/-118A User Manual Publication No. 980824-118 Rev. A
Module Operation 3-2 Astronics Test Systems
Multiple individual channels may be specified using the following
channel descriptor syntax:
@ <module address> ( <chan1> , <chan2>
, . . ., <chanN> ))
A range of channels may be specified using the following channel
descriptor syntax:
@ <module address> ( <first channel> :
<last channel> ))
The following examples illustrate the use of the channel
descriptors for the 1260-118:
OPEN (@8(0)) Open channel 0 on the 1260-118
that has module address 8.
CLOSE (@8(0,7))
Close channels 0 and 7 on the
1260-
118 that has module
address 8.
CLOSE (@2(7:12))
Close channels 7 through 12
inclusive on the 1260-118 that has
module address 2.
Reply To The
MOD:LIST?
Command
The 1260-01T returns a reply to the MOD:LIST? command. This
reply is unique for each different 1260 series switch module. The
syntax for the reply is:
<module address> : <module-specific identification string>
The <module-specific identification string> for the 1260-118 is:
1260-118 80-CHANNEL SPST 2A SWITCH MODULE
1260-118A 24-CHANNEL SPST 2A SWITCH MODULE
So, for a 1260-118 whose <module address> is set to 8, the reply
to this query would be:
8 : 1260-118 80-CHANNEL SPST 2A SWITCH
MODULE
8 : 1260-118A 24-CHANNEL SPST 2A SWITCH
MODULE