User manual

Table Of Contents
Publication No. 980935 Rev. M 3152B User Manual
Astronics Test Systems Operation 3-29
Controlling the
Sequence
Advance
Modes
Use the following commands
to control how the sequence
advances through the sequence links:
seq:adv auto This specifies continuous advance, where
the
generator steps continuously to the end of the
sequence table and then
repeats the sequence
from the beginning
. For example, if a sequence
is made of three segments,
1, 2, and 3, and
AUTO mode is used, the sequence
will proceed:
1, 2, 3, 1, 2, 3, 1, 2, 3…
, with the duration of the
loop depending upon the
loop counter specified
in the sequence table.
seq:adv trig This specifies that the 3152B
idles between links
until it senses a
valid trigger event. This mode is
available only when the 3152B is in Trigg
ered
Run mode. An attempt to select this mode
when
the 3152B is in Continuous R
un mode will
generate a settings
conflict error. After a trigger,
the generator output
resumes until it is once
again between links.
Then, the output level idles
at a DC level e
qual to the last point of the last
generated waveform. If loops (repeats) were
programmed, the segment is repeated n times
automatically before i
t begins idling. After
execution of all of the programmed loops,
the
sequencer steps to the next segment in the
sequence upon receipt of the
next valid trigger
event.
seq:adv step This Stepped Advance mode
specifies that the
sequence advances
to the next link only when a
valid trigger event has been received.
In this
mode, the 3152B
generates the first segment
cont
inuously until a trigger signal advances the
sequence to the next segment. If repeats a
re
specified in the sequence table, they are ignored
in Stepped A
dvance mode. Note that this mode
requires that the run mode be set to Continuous.
seq:adv mix In this mode, a
dvancing to the next link is
controlled by the A
dvance bit in the link
definition. “0” will cause the link to advance
automatically to the next link.
“1” will cause the
link to repeat itself continuously until a valid
trigger event has been received, and then
the
generator will begin executing the next link.
Note
that this mode requires that the run mode be
set
to Continuous.