User manual

Table Of Contents
Publication No. 980935 Rev. M 3152B User Manual
Astronics Test Systems 3152B Specifications
A-11
Trigger Delay 100 ns to 20 s, separately programmable for each
synchronized instrument
Trigger Delay Resolution 20 ns
Synchronization Frequency Range
Standard Waveforms 1.5 kHz to 100 MHz
Arbitrary and Sequenced Waveforms 2.5 MS/s to 150 MS/s, limited by a specific VXI
backplane ability to transmit high frequency
signals.
Leading Edge Offset
Description Leading edge offset is programmable for master
and slave units. Operates in conjunction with the
continuous run mode only
Offset Range <100 ns to 20 s
Resolution and Accuracy 20 ns
Options
4M Arbitrary Memory Expands the arbitrary memory from the standard
1 M to 4 M. Available on the 3100M-3152B and
3100R-3152B models.
VXlbus General Information
Module Form Single slot, C-size module
Protocol A16/A24/A32/D16 Slave, Message-Based
VXlbus Revision 3.0
SCPI Revision 1993.0
SCPI Emulation 3152A, 3152, 3151, VX4750, Specials
Logical Address Settings 1 - 255, configured via DIP switches
Shared Memory (Write only) D16/A24/A32
Front Panel LEDs Fail (Red), Access (Amber), PLL On (Amber),
Output On (Green)
Front Panel Connectors (5 BNC) Main Output, Sync Output, Trigger Input, SCLK
Input (or PM Input, internally selectable), 10 MHz
Reference input
General
Power Requirements 25W maximum
EMC Certification CE marked
Operating temperature 0 °C to 55 °C
Storage Temperature -40°C to 70 °C
Safety Designed to meet IEC 1010-1, UL 3111-1,
CSA 22.2 #1010
Workmanship Standards Conform to IPC-A-610D