User manual

Table Of Contents
3152B User Manual Publication No. 980935 Rev. M
6-34
Performance Checks Astronics Test Systems
Amplitude: 1 V/div
2. Connect the 3152B output to the oscilloscope input, channel 1.
3. Connect the 3152B SYNC to the oscilloscope input, channel 2.
4. Configure model 3152B controls as follows:
Waveform: Modulated
Modulation: AM
Carrier Freq: 1 MHz
Mod Frequency: 1 kHz
Mod Depth: 50 %
Mod Wave Sine
Sync: On
Output: On
Test Procedure:
1. Verify AM operation on the oscilloscope as follows:
Waveform: Amplitude modulated sine
Mod depth: 50 % ±5 %
Test Results Pass Fail
FSK
Equipment: Oscilloscope
Preparation:
1. Configure the oscilloscope as follows:
Time Base: 0.2 ms
Sampling Rate: 50 MS/s at least.
Trace A View: Jitter, Type: FREQ, CLK.
Trigger source: Channel 2, positive slope
Amplitude: 1 V/div.
2. Connect the 3152B output to the oscilloscope input, channel 1.
3. Connect the 3152B SYNC to the oscilloscope input, channel 2.
4. Configure model 3152B controls as follows:
Waveform: Modulated
Modulation: FSK
Carrier Freq: 2 MHz
Shift Frequency: 4 MHz
Baud Rate: 10 kHz
Marker Index: 1
Sync: On
Output: On
5. Using ArbConnection, prepare and download 10-step FSK list
with alternating “0” and “1”
Test Procedure:
1. Verify FSK operation on the oscilloscope as follows:
Waveform: Square wave
Period: 0.2 ms
Max Freq.: 4 MHz
Min Freq.: 2 MHz