Astronics Test Systems Performance Checks
6-33
Mod Frequency: 10 kHz
Re-trigger delay: 200 µs
Max Deviation: 1.25 MHz
Min Deviation: 750 kHz
Test Results Pass Fail
FM
- Arbitrary
Waveforms
Equipment: Oscilloscope
Preparation:
1. Configure the oscilloscope as follows:
Time Base: 0.2 ms
Sampling Rate: 50 MS/s at least.
Trace A View: Jitter, Type: FREQ, CLK.
Trigger source: Channel 2, positive slope
Amplitude: 1 V/div
2. Connect the 3152B output to the oscilloscope input, channel 1.
3. Connect the 3152B SYNC to the oscilloscope input, channel 2.
4. Configure model 3152B controls as follows:
Waveform: Modulated
Modulation: FM
Mod Waveform:Arbitrary
Carrier Freq: 1 MHz
FM SCLK: 2.5 MS/s
Sync: On
Output: On
5. Using ArbConnection, open the FM Composer and download
the following waveform:
Wavelength: 4000 points
Waveform: 4 sine wave cycles
Deviation: 0.5 MHz
Test Procedure:
1. Verify FM operation on the oscilloscope as follows:
Waveform: Sine
Mod Freq: 2.5 kHz
Max Deviation: 1.25 MHz
Min Deviation: 750 kHz
Test Results Pass Fail
AM
Equipment: Oscilloscope
Preparation:
1. Configure the oscilloscope as follows:
Time Base: 0.5 ms
Trigger source: Channel 2, positive slope