User manual

Table Of Contents
3152B User Manual Publication No. 980935 Rev. M
6-18
Performance Checks Astronics Test Systems
Test Procedure
1. Toggle 3152B trigger slope from positive to negative visa versa
2. Verify on the oscilloscope that the 3152B transitions are
synchronized with the slope of the trigger
Test Results Pass Fail
Trigger Level
Equipment: Oscilloscope, function generator
Preparation:
1. Configure the Oscilloscope as follows:
Termination: 50
, 20 dB feedthrough attenuator at the
oscilloscope input
Setup: As required for the test
2. Connect 3152B output to the oscilloscope input
3. Configure the function generator as follows:
Frequency 10 kHz
Run Mode: Continuous
Waveform: Square wave.
Amplitude: 1 V
4. Connect the function generator output to the 3152B TRIG IN
connector
5. Configure the 3152B as follows:
Frequency: 1 MHz
Waveform: Sine wave
Run Mode: Trigger
Trigger level: 0 V
Ch1 Output: On
Test Procedure
1. Verify that the 3152B outputs triggered waveforms spaced at
0.1 ms
2. Modify the function generator offset to +2 V and change the
3152B trigger level to +4 V. Verify that the 3152B triggered
waveforms are spaced 0.1 ms apart
3. Modify the function generator offset to -2 V and change the
3152B trigger level to -4 V. Verify that the 3152B triggered
waveforms are spaced 0.1 ms apart
Test Results Pass Fail
Backplane Trigger
Source
Equipment: Oscilloscope, auxiliary 3152B in an adjacent slot
Preparation:
1. Configure the Oscilloscope as follows: